
Copyright Gianni Industries, Inc. All Rights Reserved.
P-MU-DG10-4C Ver. A Publish:2004.09.07 Page: 2/ 2
III. Program Instruction:
Enter Program Mode:
1. Enter the master code twice (Factory master is
「
1234
」
)
→
2 beeps and the Yellow LED will light up.
→
you are now in the "programming mode".
2.
Note:
After 60 seconds if you have not entered any codes or data, the system will
automatically exit from the programming mode. After 6 wrong attempts at the master
code the lockout facility will operate.
Exiting from the program mode:
1. Press
「
#
」
to exit from the programming mode.
2.
Note:
After 60 seconds if you have not entered any codes or data, the system will
automatically exit from the programming mode. After 6 wrong attempts at the master
code the lockout facility will operate.
To Enter a User Code
:
Enter the Programming mode
1. Enter the slot position code
「*
01~
*
10
」
→
????
(
user code 4 digit
)
→
(
beep
)
→
enrolled
→
Press # to exit from the programming mode, or program other operating.
2.
Note:
The codes"0000","1234" or master code are not be used for PIN code.
To Program Relocking Timer
(
relay
):
Enter the Programming mode
A. Press
「*
20
」
Followed by the number of seconds the relay should open
→
「
05
」
=5 seconds
(
01 ~99 = seconds
)
→
(
beep
)
→
enrolled
→
Press
「
#
」
to exit from
the programming mode, or program other operating.
B. Enter
「
00
」
Sets the relay to latching mode.
(Correct code entered opens the relay,
and the relay stays open until the correct code is entered again).
To Delete a User Code
:
Enter the Programming mode
→
Press the slot position code of your choice to delete
(example "06")
→
Press
「*
06
」
→
「
0000
」
→
(
beep
)
→
delete
→
Press
「
#
」
to exit
from the programming mode, or programming other operating.
To Change the Master codes:
Enter the Programming mode, Enter
「*
00
」
Followed by the new 5 digit master code
→
(
beep
)
→
enrolled
→
Enter
「
#
」
to exit from the programming mode, or program other
operating.
IV. Wiring diagram:
Note:
The varistor or diode must be connected across the lock terminal (electromagnet...) operated
by the device. The vartistor controls the overload produced by the strike coil (EMP).