GEM ANSI Box Скачать руководство пользователя страница 2

 

Copyright Gianni Industries, Inc. All Rights Reserved.  
P-MU-DG10-4C  Ver. A  Publish:2004.09.07                                                             Page: 2/ 2

 

III. Program Instruction: 

‹

 

Enter Program Mode:  

1.  Enter the master code twice (Factory master is 

1234

2 beeps and the Yellow LED will light up.  

 you are now in the "programming mode". 

2. 

Note:

 After 60 seconds if you have not entered any codes or data, the system will 

automatically exit from the programming mode. After 6 wrong attempts at the master 
code the lockout facility will operate. 

‹

 

Exiting from the program mode: 

1. Press

#

 to exit from the programming mode. 

2. 

Note:

 After 60 seconds if you have not entered any codes or data, the system will 

automatically exit from the programming mode. After 6 wrong attempts at the master 
code the lockout facility will operate. 

‹

 

To Enter a User Code

 

       

Enter the Programming mode  

1.  Enter the slot position code 

「*

01~

10

 

????

user code 4 digit

beep

enrolled

 Press # to exit from the programming mode, or program other operating. 

2. 

Note:

 The codes"0000","1234" or master code are not be used for PIN code. 

‹

 

To Program Relocking Timer

relay

):

 

         

Enter the Programming mode 

A. Press

「*

20

Followed by the number of seconds the relay should open

05

=5 seconds

01 ~99 = seconds

beep

enrolled 

 Press 

#

 to exit from 

the programming mode, or program other operating. 

B. Enter

00

Sets the relay to latching mode.

 

(Correct code entered opens the relay, 

and the relay stays open until the correct code is entered again). 

‹

 

To Delete a User Code

 

       

Enter the Programming mode

 Press the slot position code of your choice to delete 

(example "06") 

Press

「*

06

0000

beep

delete

Press

#

 to exit 

from the programming mode, or programming other operating. 

‹

 

To Change the Master codes: 

Enter the Programming mode, Enter

「*

00

Followed by the new 5 digit master code

beep

enrolled

Enter 

#

 to exit from the programming mode, or program other 

operating. 

 

IV. Wiring diagram: 
 

 

 

Note:

 

The varistor or diode must be connected across the lock terminal (electromagnet...) operated 
by the device. The vartistor controls the overload produced by the strike coil (EMP). 

 