background image

 

______________________________________________________________________________________________________________________________

 

Rev.1 

Date 17.06.2013 

Page 1 / 14 

 

 
 

User’s Manual 

 

Sculptor 

Disctrete Pre-Amp with Eq and Peak Limiter 

 
 
 

 

 

 

 
 

 
 

 

 

Gem Audio Labs 
Tel. : 00 48 508 377 982 

[email protected] 
www.gemaudiolabs.com 

 
 

 
 

 
 

 
 

 

Содержание Sculptor

Страница 1: ...__________________________________________________________________________ Rev 1 Date 17 06 2013 Page 1 14 User s Manual Sculptor Disctrete Pre Amp with Eq and Peak Limiter Gem Audio Labs Tel 00 48 508 377 982 office gemaudiolabs com www gemaudiolabs com ...

Страница 2: ...complies with the following norms and directives 2006 95 EC LVD Low Voltage Directive 2004 108 EC EMC Electromagnetic Compatibility DIN EN 55103 1 EMC of audio equipment Emission DIN EN 55103 2 EMC of audio equipment Immunity This declaration becomes invalid by any unapproved modification of the device Wroclaw 17 06 2013 B Radziszewski SPLASH BARTOSZ RADZISZEWSKI Wietrzna 36 1 53 024 Wroclaw POLAN...

Страница 3: ...________________________________________ Rev 1 Date 17 06 2013 Page 3 14 TABLE OF CONTENTS INTRODUCTION 4 FOR SAFE OPERATION 4 CAUTION 5 FOR CORRECT OPERATION 6 THE FRONT PANEL CONTROLS AND THEIR USE 7 THE REAR PANEL 10 TECHNICAL DATA 12 ENVIRONMENTAL PROTECTION 13 LIMITED WARRANTY 14 ...

Страница 4: ...u to entirely understand how the Sculptor works and what is important to use it safely Gem Audio Labs team FOR SAFE OPERATION INSTALLATION Before You connect the power cord to the device please check fuses value and make sure that the voltage switch setting reflects the correct local power line voltage For line voltages from 100V to 120V set the switch to 115V and use 1 25A fuses slo blo 5x20mm Th...

Страница 5: ... the unit with a damaged power cord is a fire and electrical shock hazard Should this unit and AC cord be dropped or the cabinet be damaged turn the power switch off remove the power plug from the AC outlet and contact your dealer or producer If you continue using the unit without heeding this instruction fire or electrical shock may result If you notice any abnormality such as smoke odor or noise...

Страница 6: ...ctors INPUT OUTPUT are wired according to the AES standard Pin 1 shield Pin 2 hot Pin 3 cold TRS connectors INSERT SEND INSERT RETURN are wired according to the AES standard tip hot ring cold slave shield TS connectors PEAK LIMIT MASTER PEAK LIMIT SLAVE are wired unbalanced tip hot slave ground INFLUENCE ON CELL PHONE USAGE Using a cell phone mobile telephone near this unit may induce noise If noi...

Страница 7: ... LINE Line signals 10KΩ MIC Dynamic microphones 600Ω MIC 48V Only for microphones which require phantom power 600Ω WARNING Please ensure to not switch the MIC 48V position on when using ribbon microphones passive equalizers or any other device which does not accept 48V phantom power on its output C GAIN 15 position audio taper switch Mic gain range 5dB to 65dB in 5dB steps Line gain range 25 to 45...

Страница 8: ...e 20Hz 40Hz 60Hz 90Hz 150Hz 300Hz K LO BOOST Hz 7 position inductor based low frequencies boost Both peaking and shelving characters are available EQ points are 30Hz 50Hz 70Hz 100Hz 200Hz peak 100Hz 200Hz shelf The Q of the peak sharpens the more you boost L LO BOOST dB 11 position low frequencies gain switch dB points are 0dB 1dB 2dB 4dB 6dB 8dB 10dB 12dB 14dB 16dB 18dB M MID CUT Hz 6 position ac...

Страница 9: ...z 12KHz 16KHz 20KHz 27KHz U HI SHELF dB 11 position hi shelf gain switch dB points are 0dB 1dB 2dB 3dB 4dB 6dB 8dB 10dB 12dB 14dB 16dB W PEAK LIMIT HARD SOFT The Peak Limit mode switch allows to choose between two unique limit modes Hard OA202 Vintage Silicon diodes and Soft EAA91 6AL5 Vacuum Tube double diode The limiter is very specific It is unique analog brickwall solution based on metal oxide...

Страница 10: ...tly internally connected to the chassis of the Sculptor for safety It is important to change the fuse before changing the supply voltage 630mA slo blo 5x20mm for 230V 50 Hz 1 25A slo blo 5x20mm for 115V 60 Hz c INPUT Balanced input XLR wired according to the AES standard Pin 1 shield Pin 2 hot Pin 3 cold In order to avoid hum it is recommended to use the device only in balanced connections d OUTPU...

Страница 11: ...ip hot Ring cold In order to avoid hum it is recommended to use the device only in balanced connections g PEAK LIMIT LINK Use this jacks to connect two Sculptors working as a stereo couple Use unbalanced jack cable Slave shield Tip hot and connect it from one master unit MASTER OUT to second slave unit SLAVE IN Then the master unit controls thresholds in the both units h ADC An extension for optio...

Страница 12: ...ve filters Lo boost gain stepped 0dB 1dB 2dB 4dB 6dB 8dB 10dB 12dB 14dB 16dB 18dB Mid cut freq stepped 200Hz 250Hz 350Hz 500Hz 600Hz 850Hz Active filters Mid cut gain stepped 0dB 1dB 2dB 3dB 4dB 5dB 6dB 8dB 10dB 12dB 15dB Mid cut Q switch sharp wide Mid peak freq stepped 1 2KHz 1 8KHz 2 2KHz 3 9KHz 5 8KHz 8 1KHz Active filters Mid peak gain stepped 0dB 1dB 2dB 3dB 4dB 5dB 6dB 8dB 10dB 12dB 15dB Mi...

Страница 13: ...of electrical and electronic equipment The wheelie bin symbol on the product and user s manual indicates that The materials can be re used in accordance with their markings Through re use recycling of raw materials or other forms of recycling of old products you are making an important contribution to the protection of our environment Your local administrative office can advise you of the responsi...

Страница 14: ...condition that is beyond the control of the PRODUCER Warranty will not apply because of incorrect storage dropping excessive shocks corrosions dirt water or sand damages To confirm your warranty please register your Gem Audio Labs product shortly after purchase Please fill out your user registration card included in the original packaging and send it via e mail to office gemaudiolabs com or via ma...