www.geith.com
3-13
OPERATION
Releasing The Attachment Using Four Port Control Box
NOTE: To release attachment using hydraulic
pressure signal bypass, See Releasing
Attachment Using Hydraulic Pressure Signal
Bypass on Page 3-14.
AVOID SERIOUS INJURY OR DEATH
•
Keep bystanders away when engaging and
releasing attachment.
•
Keep attachment close to ground during
engaging or releasing attachment. Attachment
can fall off without warning if not fully engaged
and locked causing death or serious injury.
Park the machine on flat, level surface.
Figure 24
Lower quick coupler and attachment until slightly off the
ground
.
Figure 25
Fully crowd the quick coupler inward
.
Figure 26
. An alarm will
sound and button will illuminate.
Press unlock button (2)
within six seconds of
pressing power button. Alarm will change tone and
unlock button will illuminate.
NOTE: Unlock button (2) [Figure 26] must be pressed
within six seconds of pressing power button
or system will not operate (alarm and lights
will shut-off). If this occurs, restart the
procedure by pressing the power button.
Crowd quick coupler to build pressure until locking clasp
and sliding hook open.
NOTE: After operating pressure has been achieved in
the quick coupler system, all four buttons on
the control box will illuminate and the alarm
tone will become constant.
Figure 27
Lower the attachment to the ground and release it from
the quick coupler by rolling the quick coupler away from
attachment pins
WARNING
1
2
Содержание QC100 H1
Страница 1: ...GEITH QUICK COUPLER MANUAL www geith com PT No 823000088876 2 Released 05 2016 ...
Страница 2: ......
Страница 4: ......
Страница 6: ...www geith com ...
Страница 10: ...1 4 www geith com INTRODUCTION ...
Страница 20: ...2 10 www geith com SAFETY ...
Страница 48: ...4 10 www geith com MAINTENANCE ...
Страница 49: ...www geith com 5 1 SPECIFICATION SPECIFICATIONS Four Port Control Box ...
Страница 52: ...5 4 www geith com SPECIFICATION ...
Страница 57: ......