8
Gerhard Geiger GmbH & Co. KG | 100W1578
0920
V000
en
EN
EN
9. Operation
The GSI56..e5 can be operated with a standard locked Venetian blind switch.
Actuate the key UP to run the motor to the upper end position.
Actuate the key DOWN to run the motor to the lower end position.
10. What to do if…
Problem
Solution
Motor does not run.
• Motor not plugged in.
Please check the plug connection.
• Check connecting cable for possible
damage.
• Check the mains voltage and allow the
cause of the voltage break down to be
tested by a specialist
electrician.
Instead of in the upwards direction, motor
runs downwards.
• The control leads are interchanged.
Exchange black/brown control leads.
Motor only runs in one
direction.
• Motor in the end position.
Run motor in the opposite direction.
Readjust teh end positions, if necessary.
After running several times,
the motor breaks down and
no longer responds.
• The motor became too hot and has
switched off.
Try it again after a cooling time of about
15 min.
After setting of the lower end position the
blind only runs in DOWN direction.
• The motor has been installed upside down
(see assembly note).
11. Maintenance
The drive is maintenance-free.