4.  Safety information

 

f

The control is determined for use within the limits of the specified application 

described in point 3 hereafter. If any unauthorised changes or modifications to the 

control are made, all warranty claims with regard to this product become extinct.

 

f

Immediately after unwrapping of the control, it must be checked for damages. In the 

event of damages, the device must in no case be put into operation. Should damages 

have occurred, the supplier must be informed thereof immediately.

 

f

If it is to be assumed that a safe operation of the control cannot be guaranteed, the 

control must immediately be taken out of operation and be protected against any 

unintentional or unauthorised operation. This assumption becomes real in the event 

the housing shows damages or if the device doesn‘t work any more.

 

f

The responsibility for the compliance with the relevant regulations established by 

the power supply companies or the Union of German Electrical Engineers (VDE) is, 

according to VDE incumbent on the user and the related fitting firm.

5.  Installation

The radio sun sensor GF0031 suits for the control of sunshade installations within the limits of a 

normal room (range approx. 15 metres).  

The sun sensor must be mounted in front of or next to the sunscreen that is, the sunscreen 

must not shade the sun sensor.  

A suction cup enables to fix the device in an easy manner directly on the window pane. The 

light sensor faces outwards. It is operated using the keys S1 and S2.  

Therefore, select the installation location so that there is a direct visual contact between the 

sensor GF0031 and the receiver. 

6.  Use

Switch on sensor 

Press S2 (> 2 sec.).

The sensor is activated.

The green LED flashes three 

times for confirmation.

Switch off sensor

Press S1 (> 2 sec.).

The sensor is turned off.

The red LED flashes three times 

for confirmation.

How to test the function 

of high light intensity (sun protection closed)

Press key S2 briefly (1 sec.). After releasing the key, the transmission is carried out and the 

green LED flashes once.

How to test the function of weak light intensity (sun protection open)

Press key S1 button briefly (1 sec.). After releasing the key, the transmission is carried out and 

the red LED flashes once.

Programming of the transmitter

Activate programming mode on the sensor

Press keys S1 and S2 for 3 sec. The red and the 

green LED blink alternately.

Programming of the transmitter:

Place  the transmitter as displayed and within 

20 sec. activate the UP or DOWN key with the 

channel sun. The green LED flashes for 0,5 sec. 

on the sensor. The transmitter has been learned 

and the programming mode is exited. You can also quit the programming mode with the 

operation of S1 or S2.

OFF

ON

Light sensor

Key S1

Key S2

Solar cell

Sucker

Red

LED
Green

LED

OF

F

ON

123456

Отзывы: