ADV50 QS, SW-PW V1.11 / CTL V2.11
3
Italiano
English
General Specifications
Control System
V/f or sensorless vector control with SPWM modulation (Sinusoidal Pulse
Width Modulation)
Frequency Setting Resolution
0.01Hz
Output Frequency Resolution
0.01Hz
Torque Characteristics
Including the auto-torque/auto-slip compensation; starting torque can be
150% at 3.0Hz
Overload Endurance
150% of rated current for 1 minute
Skip Frequency
Three zones, setting range 0.1-600Hz
Accel/Decel Time
0.1 to 600 seconds (2 Independent settings for Accel/Decel time)
Stall Prevention Level
Setting 20 to 250% of rated current
DC Braking
Operation frequency 0.1-600.0Hz, output 0-100% rated current
Start time 0-60 seconds, stop time 0-60 seconds
Regenerated Braking Torque
Approx. 20% (up to 125% possible with optional brake resistor or externally
mounted brake unit, 3-15hp (2.2-11kW) models have brake chopper built-in)
C
ontr
o
l C
har
acter
isti
cs
V/f Pattern
4-point adjustable V/f pattern
Keypad
Setting by
▲
▼
Frequency
Setting
External Signal
Potentiometer-5k
Ω
/0.5W, 0 to +10VDC, 4 to 20mA, RS-485 interface; Multi-
function Inputs 3 to 9 (15 steps, Jog, motopotentiometer)
Keypad
Set by RUNand STOP
Operation
Setting
Signal
External Signal
2 wires/3 wires ((MI1, MI2, MI3)), JOG operation, RS-485 serial interface
(MODBUS), programmable logic controller
Multi-function Input Signal
Multi-step selection 0 to 15, Jog, accel/decel inhibit, 2 accel/decel switches,
counter, , external Base Block, ACI/AVI selections, driver reset, UP/DOWN
key settings, NPN/PNP input selection
Multi-function Output Indication
AC drive operating, frequency attained, zero speed, Base Block, fault
indication, overheat alarm, emergency stop and status selections of input
terminals
Oper
ati
ng C
har
acter
ist
ics
Analog Output Signal
Frequency / Current
Alarm Output Contact
Contact will be On when drive malfunctions (1 Form C/change-over contact
and 1 digital open collector output for standard type)
Operation Functions
Built-in PLC, AVR, accel/decel S-Curve, over-voltage/over-current stall
prevention, 5 fault records, reverse inhibition, momentary power loss restart,
DC braking, auto torque/slip compensation, auto tuning, adjustable carrier
frequency, output frequency limits, parameter lock/reset, vector control, PID
control, external counter, MODBUS communication, abnormal reset,
abnormal re-start, power-saving, fan control, sleep/wake frequency, 1st/2nd
frequency source selections, 1st/2nd frequency source combination,
NPN/PNP selection, parameters for motor 0 to motor 3, DEB and OOB (Out
Of Balance Detection)(for washing machine)
Protection Functions
Over voltage, over current, under voltage, external fault, overload, ground
fault, overheating, electronic thermal, IGBT short circuit, PTC
Display Keypad (optional)
6-key, 7-segment LED with 4-digit, 5 status LEDs, master frequency, output
frequency, output current, custom units, parameter values for setup and lock,
faults, RUN, STOP, RESET, FWD/REV, PLC
Built-in Brake Chopper
ADV50-2015-XXX-2MF, ADV50-2022-XXX-2M-F/2T/4-F, ADV50-2022-XXX-
2MF/2T/4F, ADV50-2037-XXX-2T/4-FADV50-2037-XXX-2T/4F, ADV50-3055-
XXX-2T/4F, ADV50-3075-XXX-2T/4-F ADV50-3075-XXX-2T/4F, ADV50-3110-
XXX-4-F, ADV50-3110-XXX-4F
Built-in EMI Filter
For 230V 1-phase and 400-460V 3-phase models.
Enclosure Rating
IP20
Pollution Degree
2
Installation Location
Altitude 1,000 m or lower, keep from corrosive gasses, liquid and dust
Ambient Temperature
-10
o
C to 50
o
C (40
o
C for side-by-side mounting) Non-Condensing and not
frozen
E
n
viro
me
nta
l
C
ondi
tio
ns
Storage/ Transportation
Temperature
-20
o
C to 60
o
C