manualshive.com logo in svg
background image

EXT-IP-2-RS2322

User Manual

IP to RS-232 

Converter

*Preferred

Release A4

Содержание EXT-IP-2-RS2322

Страница 1: ...EXT IP 2 RS2322 User Manual IP to RS 232 Converter Preferred Release A4...

Страница 2: ...d from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 To...

Страница 3: ...articular purpose all of which are expressly disclaimed 1 Proof of sale may be required in order to claim warranty 2 Customers outside the US are responsible for shipping charges to and from Gefen 3 C...

Страница 4: ...Time Fax 818 772 9120 Email support gefen com Web http www gefen com Mailing Address Gefen LLC c o Customer Service 20600 Nordhoff St Chatsworth CA 91311 Product Registration Register your product her...

Страница 5: ...s product Syner G is also used to configure this product on a network Download the application here http www gefen com synerg IP to 2 x RS 232 Converter is a trademark of Gefen LLC 2015 Gefen LLC All...

Страница 6: ...me of the author may not be used to endorse or promote products derived from this software without specific prior written permission THIS SOFTWARE IS PROVIDED BY THE AUTHOR AS IS AND ANY EXPRESS OR IM...

Страница 7: ...32 baud rate and line delay for each RS 232 port Gefen Discovery Tool compatible Field upgradable firmware via Web server interface Locking power supply connector Surface mountable Packing List The IP...

Страница 8: ...gram 4 2 Basic Operation IP Configuration 8 Using Syner G 8 RS 232 Interface 10 RS 232 Interface 10 RS 232 Settings 10 Web Interface 11 Using the built in Web Interface 11 RS 232 12 Network tab 18 Sys...

Страница 9: ...This page left intentionally blank...

Страница 10: ...This page left intentionally blank...

Страница 11: ...IP to RS 232 Converter 1 Getting Started...

Страница 12: ...ntrol RS 232 2 IP to 2xRS 232 Converter RS 232 1 Power IP Reset EXT IP 2 RS2322 Gefen 5V DC IP control RS 232 2 IP to 2xRS 232 Converter RS 232 1 Power IP Reset EXT IP 2 RS2322 Gefen 5V DC IP control...

Страница 13: ...for more information 3 Power This LED will glow bright blue when the unit is powered 4 5V DC Connect the included 5V DC power supply to this power receptacle 5 IP control Connect an Ethernet cable bet...

Страница 14: ...nect an RS 232 device to each of the RS 232 ports RS 232 1 and RS 232 2 on the IP to 2 x RS 232 Converter 3 Connect the included 5V DC locking power supply to the 5V DC power receptacle on the IP to 2...

Страница 15: ...This page left intentionally blank...

Страница 16: ...This page left intentionally blank...

Страница 17: ...page 7 IP to RS 232 Converter 2 Basic Operation...

Страница 18: ...G Software Suite The Gefen Syner G Software Suite is free software that is available from the Gefen Web site 1 Download and install the Gefen Syner G Software Suite Download the application here http...

Страница 19: ...k 6 Click the Save button at the bottom right corner of the screen 7 Click the Reboot button 8 Click the Web GUI link above the Reboot button to access the built in web interface The following table l...

Страница 20: ...ata bits 8 Parity None Stop bits 1 Hardware flow control None The command set on the following pages can be used to control the settings of the IP to 2 x RS 232 Converter via RS 232 DA 15 DE 9 DB 25 D...

Страница 21: ...the section IP Configuration page 8 The built in Web interface is divided into three pages RS 232 Network and System Each main page is represented by a tab at the top of the screen The RS 232 page wi...

Страница 22: ...ct RS 232 Port Select the RS 232 port from the drop down list Options 1 2 Description Enter a description for the device that is connected to the selected RS 232 port RS 232 Mode Select the desired mo...

Страница 23: ...9200 28800 Data Bits Select the number of data bits in each character from this drop down list For most applications 8 data bits should be selected 9 data bits are rarely used Options 8 9 Parity Selec...

Страница 24: ...10000 Force Send ms If no data is received from the controlled device within the specified time interval send the collected data to the control system Range 0 30 Force Send bytes If the specified num...

Страница 25: ...ons Enable checked Disable unchecked Start Delimiter Value This value can be up to three ASCII characters 3 bytes in length The value must be entered in hexadecimal e g 0D0A which is CR LF The Start F...

Страница 26: ...lue can be up to three ASCII characters 3 bytes in length The value must be entered in hexadecimal Range 00 FF wildcard characters such as are acceptable TCP Port Enter the TCP port in this field Rang...

Страница 27: ...te 0 255 Destination Port Enter the destination port in this field Range 1024 65535 UDP Echo Useful in troubleshooting and measuring response times and end to end connectivity Options Enable checked D...

Страница 28: ...IP to RS 232 Converter The MAC address cannot be changed Mode Select the network mode from the drop down list Options Static DHCP IP Address Enter the IP address of the IP to 2 x RS 232 Converter Rang...

Страница 29: ...Operation Web Interface Gateway The gateway router IP address to with the IP to 2 x RS 232 Converter is connected Range per byte 0 255 HTTP Port Select the network mode from the drop down list Range p...

Страница 30: ...nect Forces password prompt for Telnet sessions Options Enable checked Disable unckecked User Name Displays the user name for TCP sessions The user name cannot be changed Old Password Type the current...

Страница 31: ...asked when entered The password is case sensitive Maximum length 8 characters Confirm Password Re type the new password in this field The password must match the same password that was entered in the...

Страница 32: ...tion Web Interface Enable UDP Access Enables or disables UDP access Options Enable checked Disable unckecked UDP Port Sets the UDP port Range 1 1024 Enable UDP Echo Enables or disables UDP echo Option...

Страница 33: ...n this field Range per byte 0 255 Destination UDP Port Type the remote UDP port in this field Range 1 1024 Enable Discovery Enables or disables discovery mode This feature must be enabled in order for...

Страница 34: ...Configuration Saves the current configuration of the IP to 2 x RS 232 Converter to a file Browse Restore Configuration Selects the configuration file to load See the Download button above Restore Cli...

Страница 35: ...Reset Use these check boxes to select the type of factory reset to perform Placing a check mark in the desired check box will select the type of reset Options Select All resets network and RS 232 sett...

Страница 36: ...This page left intentionally blank...

Страница 37: ...IP to RS 232 Converter 3 Advanced Operation...

Страница 38: ...the specified RS 232 port set_start_del Sets the Start Frame delimiter set_tcp_br_port Sets the TCP bridge listening port set_tcp_term_port Sets the TCP terminal listening port set_telnet_pass Sets th...

Страница 39: ...hardware version of the IP to RS 232 Converter system_wide_reset Restarts the IP to 2 x RS 232 Converter according to the supplied parameter use_discovery Enables or disables discovery mode use_tcp_a...

Страница 40: ...elp set_add_delim Cmd set_add_delim Set Add delimiter mode Syntax set_add_delim param1 pram2 Param1 Serial Port 1 2 Param2 1 On 0 Off e g set_add_delim 1 0 help full Cmd show_serial_params Show Serial...

Страница 41: ...et_udp_rport use_udp_access use_udp_echo use_tcp_access set_serial_params show_serial_params set_serial_mode show_serial_mode show_serial_connect set_serial_descr show_serial_descr set_tcp_br_port set...

Страница 42: ...les the option to include a delimiter as part of the data sent to the control system Syntax set_add_delim param1 param2 Parameters param1 Value 1 2 param2 State 0 1 Value Description 0 Off 1 On Exampl...

Страница 43: ...cription The device description cannot exceed 30 characters in length Syntax set_device_descr param1 Parameters param1 Description 30 chars max Example set_device_descr LivingRoom_Bridge2 Device Descr...

Страница 44: ...ed in hexadecimal Before executing this command the Start Delimiter must be set using the set_start_del command Syntax set_end_del param1 param2 param3 Parameters param1 Serial port 1 2 param2 State 0...

Страница 45: ...notation The matrix must be rebooted after executing this command The default gateway is 192 168 1 1 Syntax sgateway param1 Parameters param1 Gateway Example set_gateway 10 5 64 1 New IP Gateway set t...

Страница 46: ...g port The unit must be rebooted after executing this command The default port setting is 80 Syntax set_http_port param1 Parameters param1 Port 1 1024 Example set_http_port 82 New HTTP port set to 82...

Страница 47: ...using dot decimal notation The unit must be rebooted after executing this command The default IP address is 192 168 1 72 Syntax set_ipadd param1 Parameters param1 IP address Example set_ipadd 10 5 64...

Страница 48: ...ot decimal notation The unit must be rebooted after executing this command The default net mask is 255 255 255 0 Syntax snetmask param1 Parameters param1 Net mask Example snetmask 255 255 0 0 New IP M...

Страница 49: ...mode Syntax set_send_byte_cnt param1 Parameters param1 Serial port 1 2 param2 Byte count 0 255 Example set_send_byte_cnt 1 100 UART 1 bridging send byte count limit is set to 100 bytes Related Comman...

Страница 50: ...elimiter have been set If no data has been collected for the specified time the data is sent without waiting for the End Delimiter Syntax set_send_time_out param1 Parameters param1 Serial port 1 2 par...

Страница 51: ...scription cannot exceed 20 characters in length The default description is None Syntax set_serial_descr param1 param2 Parameters param1 Port 1 2 param2 Description 20 chars max Example set_serial_desc...

Страница 52: ...for all serial ports 1 2 is TCP Bridge mode Syntax set_serial_mode param1 param2 Parameters param1 Port 1 2 param2 State 1 3 Mode Description 1 TCP bridge 2 UDP bridge 3 Terminal mode Example set_ser...

Страница 53: ...al_params param1 param2 param3 param4 param5 param6 Parameters param1 Port 1 3 param2 Word length 5 8 param3 Stop bits 1 2 param4 Parity Parity Description n None e Even o Odd m Mark s Space param5 Ba...

Страница 54: ...ion Commands Advanced Operation Example set_serial_params 1 8 1 N 19200 1000 Serial port 1 parameters Word length 8 bits Stop bits 1 bit Parity None Baud Rate 19200 Bps Line Delay 1000 ms Related Comm...

Страница 55: ...always be specified before the End Delimiter Syntax set_start_del param1 param2 param3 Parameters param1 Serial port 1 2 param2 State 0 1 Mode Description 1 TCP bridge 2 UDP bridge 3 Terminal mode pa...

Страница 56: ...ified serial port The default port settings for RS 232 1 and RS 232 2 ports are 49200 and 49201 respectively Syntax set_tcp_br_port param1 param2 Parameters param1 Serial port 1 2 param2 TCP port 1 65...

Страница 57: ...ort Sets the TCP terminal listening port The default port settings is 23 Syntax set_tcp_term_port param1 Parameters param1 TCP port 1 65535 Example set_tcp_term_port 23 New TCP Terminal port set to 23...

Страница 58: ...gth param3 is used to verify the new password The default password is Admin Syntax set_telnet_pass param1 param2 param3 Parameters param1 Old password 20 chars max param2 New password 20 chars max par...

Страница 59: ...r RS 232 1 and RS 232 2 ports are 50200 and 50201 respectively Syntax set_udp_br_port param1 param2 Parameters param1 Serial port 1 2 param2 Port 1 65535 Example set_udp_br_port 1 50200 UDP Bridge 1 p...

Страница 60: ...UDP bridge echo Syntax set_udp_echo_br param1 param2 Parameters param1 Serial port 1 2 param2 State 0 1 State Description 0 Disabled 1 Enabled Example set_udp_echo_br 1 1 The echo of UDP Bridge port...

Страница 61: ...ts the UDP server listening port Syntax set_udp_port param1 Parameters param1 Serial port 1 65535 Example set_udp_port 50007 New UDP server port set to 50007 Related Commands set_udp_br_port set_udp_r...

Страница 62: ...be entered in dot decimal notation Syntax set_udp_remote_br param1 param2 param3 Parameters param1 Serial port 1 2 param2 Address param3 Remote port 1 65535 Example set_udp_remote_br 1 192 168 1 70 5...

Страница 63: ...must be entered using dot decimal notation Each digit can range between 0 and 255 Syntax set_udp_rip param1 Parameters param1 IP address Example set_udp_rip 192 168 1 205 New Remote UDP IP set to 192...

Страница 64: ...Sets the remote UDP listening port The default port settings is 50008 Syntax set_udp_rport param1 Parameters param1 Port 1 65535 Example set_udp_rport 50006 New UDP Remote port set to 50006 Related Co...

Страница 65: ...s 1 Delimiter Param s in bridge mode UART 1 Line Delay 1000ms Time To Force Send 30ms Count Byte To Force Send 100 Add Delimiters In Data False Use Start Delimiter False Start Delimiter Size 1 Start D...

Страница 66: ...Operation Commands Advanced Operation show_device_descr Displays the device description Syntax show_device_descr Parameters None Example show_device_descr Device Description IP_BRIDGE Related Commands...

Страница 67: ...50007 Enable UDP Echo Disabled UDP Remote IP 192 168 1 80 UDP Remote Port 50008 TCP Bridge 1 Port 49200 TCP Bridge 2 Port 49201 UDP Local Bridge 1 Port 50200 UDP Remote Bridge 1 IP 192 168 1 180 Port...

Страница 68: ...es the flashing of the LED on the device When enabled the LED indicator will flash red and blue The default setting is disabled Syntax show_me param1 Parameters param1 State State Description 0 Disabl...

Страница 69: ...ion show_serial_descr Displays the description of the specified serial port Syntax show_serial_descr param1 Parameters param1 Port 1 2 Example show_serial_descr 1 Serial port 1 Description DVD_Ctrl Re...

Страница 70: ...ced Operation show_serial_mode Displays the mode of the specified serial port Syntax show_serial_mode param1 Parameters param1 Port 1 2 Example show_serial_mode 1 Serial port 1 working mode is TCP Bri...

Страница 71: ...t settings of the specified serial port Syntax show_serial_params param1 Parameters param1 Port 1 2 Example show_serial_params 1 Serial port 1 parameters Word length 8 bits Stop bits 1 bit Parity None...

Страница 72: ...ation Commands Advanced Operation show_telnet_pass Displays the current TCP terminal password Syntax show_telnet_pass Parameters None Example show_telnet_pass TCP Terminal password b055man Related Com...

Страница 73: ...ds Advanced Operation show_ver_data Displays the current software and hardware version Syntax show_ver_data Parameters None Example show_ver_data Firmware version 1 48 Release date May 12 2014 Release...

Страница 74: ...pplied parameter Syntax system_wide_reset param1 Parameters param1 Value 0 3 Value Description 0 Reboot only 1 Reset IP settings 2 Reset serial port settings 3 Reset all and reboot Example system_wide...

Страница 75: ...P to 2 x RS 232 Converter will not be discoverable when using the Gefen Discovery Tool The default setting is enabled Syntax use_discovery param1 Parameters param1 State State Description 0 Discovery...

Страница 76: ...ed before using RS 232 command to configure the IP to 2 x RS 232 Converter Syntax use_tcp_access param1 Parameters param1 Value 0 1 Value Description 0 Disable TCP access 1 Enable TCP access Example u...

Страница 77: ...during terminal sessions Syntax use_tcp_term_pass param1 Parameters param1 Value 0 1 Value Description 0 Do not use password 1 Require password Example use_tcp_term_pass 1 TCP Terminal password at lo...

Страница 78: ...isables UDP access Syntax use_udp_access param1 Parameters param1 Value 0 1 Value Description 0 Disable UDP access 1 Enable UDP access Example use_udp_access 1 UDP Access is set to Enabled Related Com...

Страница 79: ...ables UDP echo Syntax use_udp_echo param1 Parameters param1 Value 0 1 Value Description 0 Disable UDP echo 1 Enable UDP echo Example use_udp_echo 1 UDP echo is set to Enabled Related Commands set_udp_...

Страница 80: ...This page left intentionally blank...

Страница 81: ...IP to RS 232 Converter 4 Appendix...

Страница 82: ...None RS 232 Mode TCP Bridge Baud Rate 19200 Data Bits 8 Parity None Stop Bits 1 Bridging Settings Line Delay ms 0 Force Send ms 30 Force Send bytes 100 Add Delimiters to data sent Disabled Use Start...

Страница 83: ...Enable TCP Access Disabled Require Password on Connect Disabled User Name Admin cannot be changed Old Password default password is Admin New Password Confirm New Password Terminal Port 23 UDP Settings...

Страница 84: ...e IP control 1 x RJ 45 Power 1 x 5V DC locking Power indicator 1 x LED blue IP Reset button 1 x Tact type recessed Operational Power 5V DC Power consumption 1W max Physical Dimensions W x H x D 4 3 x...

Страница 85: ...This page left intentionally blank...

Страница 86: ...0 545 6900 818 772 9100 fax 818 772 9120 www gefen com support gefen com Stretch it Switch it Split it Gefen s got it 20600 Nordhoff St Chatsworth CA 91311 1 800 545 6900 818 772 9100 fax 818 772 9120...

Отзывы: