SERVICE SWITCH USAGE GUIDE
Gefen CAT5 Extreme products (sender and receiver) both contain a pair of service
switches (also called dip switches) located underneath the unit. These service
switches are used to select from sets of confi gurations that will equalize the signal to
best match the conditions in your setup. For the CAT5•5500HD, there are 1 set of
switches for each monitor under both the sender and receiver units. The switches are
hidden beneath black stickers. Each bank of dip switches have 4 switches. Switches 3
and 4 are not used. (*Note: Adjustments should be done with sources and display on.)
Sender Dip Switch Settings
Setting
Switch 1 Switch 2
No Boost
OFF
ON
Normal Boost (Default)
OFF
OFF
Strong Boost
ON
OFF
Undefi ned
ON
ON
Receiver Dip Switch Settings
Setting
Switch 1 Switch 2
No EQ (Default)
OFF
OFF
EQ Setting 2
ON
OFF
EQ Setting 3
OFF
ON
Maximum EQ
ON
ON
Adjustment Guidelines:
1)
Strong boost should not be used on stranded cables. Strong boosting will cause
pixels or no picture on these cables.
2)
Using the wrong settings will not damage the units; it will either produce no
image or a noisy image.
3)
To eliminate the possibility of cross talk and interference, cables must be
terminated with 568B scheduling. (See page 8 for details)
Содержание EXT-CAT5-5500HD
Страница 1: ...www gefen com Cat5 5500HD E X T C A T 5 5 5 0 0 H D U S E R M A N U A L ...
Страница 7: ...4 CAT5 5500HDS BACK PANEL LAYOUT 1 2 3 4 5 6 7 8 Sender ...
Страница 9: ...6 CAT5 5500HDR BACK PANEL LAYOUT 1 2 3 4 5 6 7 8 Receiver ...
Страница 12: ...9 CAT5 5500HD WIRING DIAGRAM ...
Страница 17: ...14 ...