background image

8x8 DVIKVM

Dual Link Matrix

w/ Push Button 

Control

GEF-DVIKVM-848DL-PB

User Manual

www.gefenpro.com

1080P

Содержание GEF-DVIKVM-848DL-PB

Страница 1: ...8x8 DVIKVM Dual Link Matrix w Push Button Control GEF DVIKVM 848DL PB User Manual www gefenpro com 1080P...

Страница 2: ......

Страница 3: ...Write To Gefen LLC c o Customer Service 20600 Nordhoff St Chatsworth CA 91311 www gefenpro com support gefenpro com Notice Gefen LLC reserves the right to make changes in the hardware packaging and a...

Страница 4: ...tandby Mode 16 Cycling between Information Screens 17 Activating Deactivating Standby Mode 17 Saving the Downstream EDID to Local Memory 19 Saving the Default EDID to Local Memory 20 Saving the curren...

Страница 5: ...3840 x 2400 are supported Audio can be routed with the video or independently from the video using mini stereo cables to provide full multimedia content for digital signage applications The front pan...

Страница 6: ...rce devices For maximum compatibility it is recommended that only one compatible common resolution be used by all of the source devices Advanced EDID features and IP configuration features are accessi...

Страница 7: ...32 interface for remote control via a computer or control automation devices IP Control Output masking command IR Remote Control IR Extender Power On Off switch Internal power supply Grounding Termina...

Страница 8: ...4 PANEL LAYOUT Front Panel 4 5 6 1 2 3 7...

Страница 9: ...r off using this switch 4 LCD Display Displays the current routing status of the Matrix and is also used to manage source routing 5 Power Indicator This LED indicator will glow bright red when the pow...

Страница 10: ...6 PANEL LAYOUT Back Panel 4 2 1 5 6 7 8 9 10 11 3...

Страница 11: ...Ports 1 8 Connect DVI source devices to these ports 5 IP Control Interface Connect to this port to control the 8x8 DVIKVM Dual Link Matrix using IP Control See page 51 for more information 6 IR Extend...

Страница 12: ...s 3 Connect the included AC power cable to the power receptacle on the rear panel of the GefenPRO 8x8 DVIKVM Dual Link Matrix Connect the opposite end of the cable into an available electrical outlet...

Страница 13: ...the 8x8 DVIKVM Dual Link Matrix is a 16 character 2 line display This display is used to aid in performing routing commands as well as displaying additional system information When the unit is powere...

Страница 14: ...ressed 2 Source Monitor Selection Buttons 1 8 These buttons are used to select the source and monitor See page 13 for information on using the IR Remote Control unit 1 2 NOTE An Activity Indicator tha...

Страница 15: ...into the open battery slot The positive side of the battery should be facing up 3 Replace the battery cover The Remote Control unit ships with two batteries One battery is required for operation and...

Страница 16: ...2 1 2 Remote Channel 2 Remote Channel 0 Default Remote Channel 1 Remote Channel 3 Left Picture of the opened rear battery compartment of the IR remote showing the exposed DIP Switch bank between the...

Страница 17: ...select the monitor where the source will be routed The second step is to select the source Example 1 Route the source device connected to In 7 to the monitor connected to Out 3 1 Press button 3 monito...

Страница 18: ...de 2 Press any Input on the bottom row of buttons 1 8 The system indicates the current routing status 3 Press the desired Output button One or more Output buttons may be selected 4 Press the Set butto...

Страница 19: ...l buttons are pressed by accident Locking the Matrix also prevents changes using the IR Remote Control Unit 1 Press the Lock button to activate System Lock Mode 2 Press the Lock button a second time t...

Страница 20: ...ING THE 8X8 DVIKVM DUAL LINK MATRIX Cycling between Information Screens Press the Cancel button while in Status Check Mode to cycle through the Information Screens Cancel Cancel Cancel Press the Cance...

Страница 21: ...ivating Standby Mode Press and hold the Cancel button for 5 seconds to activate or deactivate Standby Mode Saving the Downstream EDID to Local Memory 1 Press EDID button once to activate DSTOLO Downst...

Страница 22: ...s the Output button to select the EDID data source 3 Press the Input button to select EDID data destination 4 Press the Set button to complete the operation The system will remain in DSTOLO mode Press...

Страница 23: ...y 1 Press the EDID button twice to activate DETOLO Default EDID To Local Mode 2 Press the Input button to select EDID data destination 3 Press the Set button to complete the operation The system will...

Страница 24: ...e see page 14 then press the PreSet button twice to activate Preset Mode 2 Press an Input button 1 8 to store the current routing state 3 Press the Set button to complete the operation The system will...

Страница 25: ...the PreSet button once to activate Recall Preset Mode 2 Press the Input button 1 8 of the routing state to be recalled 3 Press the Set button to complete the operation The system will remain in Recall...

Страница 26: ...ead of powering down the output device The masking process is identical for masking or unmasking outputs 1 Press the Mask button to activate Mask Mode 2 Select the Output to be masked 3 Press the Set...

Страница 27: ...l None 5 4 3 2 1 9 8 7 6 1 2 3 4 5 6 7 8 9 Only Pins 2 RX 3 TX and 5 Ground are used on the RS 232 serial interface IMPORTANT When sending RS 232 commands a carriage return and a line feed character m...

Страница 28: ...Read downstream EDID and sends to serial port predidst Prints EDID details prloedid Read Input Local EDID and sends to serial port dynamic_edid Command The dynamic_edid command provides the ability to...

Страница 29: ...aram2 0 then the EDID in the specified bank is copied to all eight inputs Examples p edidbatolo 2 3 Finished reading EDID from bank 2 Finished loading EDID to local 3 edidbatolo 4 0 Finished reading E...

Страница 30: ...param1 Input 1 8 Notes If param1 0 then all 8 DVI inputs will be set to the Default EDID Examples p ediddetolo 7 Finished loading EDID to local 7 ediddetolo 0 Finished loading EDID to local 1 Finishe...

Страница 31: ...on reads the downstream EDID and stores it to a specified EDID bank Syntax y ediddstoba param1 param2 Parameters param1 A downstream monitor 1 8 param2 EDID bank offset 1 5 2 Example p ediddstoba 4 2...

Страница 32: ...then the downstream EDID is stored to all 8 DVI inputs Examples p ediddstolo 2 3 Finished reading EDID from output 2 Finished loading EDID to local 3 ediddstolo 2 0 Finished reading EDID from output 2...

Страница 33: ...id function secures the Local EDID and disables the automatic loading of the downstream EDID after the Matrix is powered on Syntax y lock_edid param1 Parameters param1 Input 0 1 Value Meaning 0 Disabl...

Страница 34: ...0 0x95 0x0F 0xB3 0x00 0xA9 0x40 0x02 0x3A 0x80 0x18 0x71 0x38 0x2D 0x40 0x58 0x2C 0x45 0x00 0xA0 0x5A 0x00 0x00 0x00 0x1E 0x66 0x21 0x50 0xB0 0x51 0x00 0x1B 0x30 0x40 0x70 0x36 0x00 0xA0 0x5A 0x00 0x0...

Страница 35: ...0x00 0x95 0x0F 0xB3 0x00 0xA9 0x40 0x02 0x3A 0x80 0x18 0x71 0x38 0x2D 0x40 0x58 0x2C 0x45 0x00 0xA0 0x5A 0x00 0x00 0x00 0x1E 0x66 0x21 0x50 0xB0 0x51 0x00 0x1B 0x30 0x40 0x70 0x36 0x00 0xA0 0x5A 0x00...

Страница 36: ...function displays a table containing details relating to the Local EDID and the monitor name Syntax y prdsedid Parameters None Example p predidst Input Source Name 1 Default GEFEN_XPT_DL 2 Output_1 3...

Страница 37: ...1 0x14 0x01 0x03 0x80 0x50 0x2D 0x78 0x0A 0x0D 0xC9 0xA0 0x57 0x47 0x98 0x27 0x12 0x48 0x4C 0x21 0x4F 0x00 0x81 0x00 0xA9 0x40 0xD1 0x00 0x71 0x40 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x30 0x2A 0x0...

Страница 38: ...for password when using Telnet set_telnet_port Sets the Telnet listening port set_telnet_username Sets the user name for the login procedure sgateway Sets the IP gateway address show_telnet_pass Promp...

Страница 39: ...me command sets enables disables the Telnet welcome message on login Syntax y display_telnet_welcome param1 Parameters param1 State 0 1 State Meaning 0 Do not display welcome message 1 Display welcome...

Страница 40: ...tings for the matrix Syntax y ipconfig Parameters None Example p ipconfig TCP IP settings MAC add 00 1C 91 01 50 07 IP add 192 168 1 72 Net Mask 255 255 255 0 Gateway 192 168 2 1 Web Server Port 80 Te...

Страница 41: ...fter executing this command Example p resetip Reset ip configuration to factory default set_http_port Command The set_http_port command sets the Web server listening port Syntax y set_http_port param1...

Страница 42: ...he default password is Admin The matrix must be rebooted after executing this command Example p set_telnet_pass reindeer Telnet password updated to reindeer set_telnet_port Command The set_telnet_port...

Страница 43: ...ust be rebooted after executing this command Example p set_telnet_username andrew Telnet login updated to andrew sgateway Command The sgateway sets the IP gateway router address Dot decimal notation m...

Страница 44: ...rd for login if required Syntax y show_telnet_pass Example p show_telnet_pass Telnet password reindeer show_telnet_username Command The show_telnet_username command returns the user name required for...

Страница 45: ...are version 1 Firmware Release version 2 0 30 Release data Apr 9 2012 Boot loader version 1 6 sipadd Command The sipadd command sets the IP address of the matrix Dot decimal notation must be used when...

Страница 46: ...to 255 255 255 0 The matrix must be rebooted after executing this command Example p snetmask 255 255 0 0 New IP Mask set to 255 255 0 0 use_telnet_pass Command The use_telnet_pass command requires or...

Страница 47: ...ng masking state to a preset a Routes audio independently from video r Routes the specified inputs to the specified outputs s Routes the specified input to all outputs callpreset Command The callprese...

Страница 48: ...associated output e g 1 1 2 2 3 3 etc Example p saudio 2 Independent audio route input 2 to all outputs saudio 0 Independent audio routing 1 1 2 2 savepreset Command The savepreset command saves the c...

Страница 49: ...a Command The a command routes the audio independently from the video Syntax y a param1 param2 param3 param9 Parameters param1 Audio input 1 8 param2 Audio output 1 8 Example p a 1 2 3 Audio input 1...

Страница 50: ...the specified input is routed to all outputs 2 Examples p r 7 3 4 5 6 1 2 Input 7 is routed to outputs 3 4 5 6 1 2 If Dynamic EDID see page 24 is enabled then the last output in the list will be save...

Страница 51: ...47 RS 232 TELNET COMMANDS s Command The s command routes the specified input to all outputs Syntax y s param1 Parameters param1 Input 1 8 Example p s 1 All outputs are routed to input 1...

Страница 52: ...ut Unmasks the selected output s maskaud Command The maskaud command masks the selected audio output s Syntax y maskaud param1 param2 Parameters param1 Output 1 8 param2 State 0 1 Value Meaning 0 Acti...

Страница 53: ...ified outputs Syntax y maskout param1 param2 Parameters param1 Output 1 8 param2 State 0 1 Value Meaning 0 Active 1 Mask Notes The current masking state will be lost if power is interrupted or if the...

Страница 54: ...el s Syntax y maskusb param1 param2 Parameters param1 Output 1 8 param2 State 0 1 Value Meaning 0 Active 1 Mask Notes The current masking state will be lost if power is interrupted or if the masking s...

Страница 55: ...The unmaskout command unmasks the specified outputs If param1 0 then all outputs will be unmasked Syntax y unmaskout param1 param8 Parameters param1 Output 1 8 Examples p unmaskout 3 5 7 Activate out...

Страница 56: ...routing help Displays all available commands lock_fo Toggles the 5V lock power state prpreset Prints the routing preset table set_input_name Specifies a name for an input set_ir Sets the IR channel of...

Страница 57: ...xample p activebolo To download the file DVI8x8DL please type the command activebolo 0 To download the file USBAUD8x8 please type the command activebolo 2 audswitch Command The audswitch command enabl...

Страница 58: ...e g Output 1 Input 1 Syntax y fadefault Parameters None Example p fadefault Return to factor default Loading default EDID Routed 1 1 2 2 Finished loading EDID to local 1 Finished loading EDID to local...

Страница 59: ...ll a routing and mask state preset Syntax callpreset param1 Param1 1 16 preset e g callpreset 2 lock_fo Command The lock_fo enables disables the power lock state Enabling this feature will store the 5...

Страница 60: ...rs None Example p prpreset PreSet Out1 2 3 4 5 6 7 8 1 M 0 M 0 M 0 M 0 M 0 M 0 M 0 M 0 2 M 0 M 0 M 0 M 0 M 0 M 0 M 0 M 0 3 M 0 M 0 M 0 M 0 M 0 M 0 M 0 M 0 4 M 0 M 0 M 0 M 0 M 0 M 0 M 0 M 0 5 M 0 M 0 M...

Страница 61: ...core character _ to separate characters Syntax y set_input_name param1 param2 Parameters param1 Input 1 16 param2 Name Example p set_input_name 5 computer1 computer1 is assigned to input 5 set_ir Comm...

Страница 62: ...required use the underscore character _ to separate characters Syntax y set_output_name param1 param2 Parameters param1 Output 1 16 param2 Name Example p set_output_name 3 display_3 display_3 is assig...

Страница 63: ...es voltage information for the matrix Syntax y show_voltage Parameters None Example p show_voltage Voltage 3 3 measured 3344 mV Voltage 5 measured 5036 mV Voltage 12 measured 11905 mV Voltage 1 2 meas...

Страница 64: ...module of fiber optic extenders which require 5V Syntax y f param1 param2 Parameters param1 Input 1 8 param2 State 0 1 State Meaning 0 Disable 5V 1 Enable 5V Example p f 1 1 Enable FO 1 WARNING Befor...

Страница 65: ...s receiving a dual link signal then the Link status will be set to Dual If a single link source is used then the Link status will be set to Single Syntax y l Parameters None Example p l Input Signal L...

Страница 66: ...Parameters None Example p m Output Input HPD Status AUDIOin Output_1 Input_1 LOW ACTIVE 1 Output_2 Input_2 HIGH ACTIVE 1 Output_3 Input_3 LOW ACTIVE 1 Output_4 Input_4 LOW ACTIVE 1 Output_5 Input_5 LO...

Страница 67: ...2 Launch a terminal emulation program e g HyperTerminal and use the following settings Baud Rate 19200 Data Bits 8 Parity None Stop Bits 1 3 Enter the following command with the IP address to be assi...

Страница 68: ...plays the current routing status of each input and output on the matrix Refresh Click to refresh the Matrix Status screen Auto Refresh Check this box to enable Auto Refresh The Auto Refresh function a...

Страница 69: ...route a source place a check mark next to each Output Next click the radio button next to the desired Input Press the Switch button to apply the routing change Audio switching can also be managed thr...

Страница 70: ...o switching Click the Yes radio button to enable independent audio switching To disable click the No radio button Once independent audio switching is enabled click the radio button next to the Input w...

Страница 71: ...he Save et button to save the preset Recall Preset Click the down arrow on the pull down list to select the routing state 1 16 to recall Click the Recall Preset button to recall the preset Presets Pro...

Страница 72: ...tton to save changes See page 48 for naming restrictions Save Input Name Select the DVI input to rename from the pull down list Type the name of the input in the Input Name field Click the Save Input...

Страница 73: ...Displays the current EDID status for each input on the matrix and indicates the current Lock State Refresh Click to refresh the Matrix Status screen Auto Refresh Check this box to enable Auto Refresh...

Страница 74: ...next to the input s that should be set to the default EDID Click the Set Default EDID button to apply the default EDID to the selected inputs Set Input to Default EDID Press this button from the Manag...

Страница 75: ...the EDID data from the file The EDID file must be in bin format Click the Browse button to locate the EDID on the computer Click the Load EDID file button to upload the EDID file to the matrix Upload...

Страница 76: ...radio button next to the output containing the EDID to be downloaded Click the Download EDID File to PC button to confirm the change The downloaded EDID file will be in bin format Download EDID Press...

Страница 77: ...input or output containing the EDID to copy Note that only a single input or output can be selected at a time Place a check mark next to the input s where the EDID will be copied Click the Set EDID bu...

Страница 78: ...tream EDID after the Matrix is powered on Select the radio button next to the Off or On option then click the Update EDID Lock State button to apply the change The EDID Lock State has no effect when t...

Страница 79: ...splays the current masking status for each output Mask Click the Mask button to mask the selected output If the output is already masked then the button will read Active enabled Click the Active butto...

Страница 80: ...g port and Telnet port Note that the MAC address can not be changed Click the Save button to apply changes The matrix must be rebooted for the changes to take effect Telnet Login Settings Sets the use...

Страница 81: ...77 WEB INTERFACE Backup Restore The Backup Restore feature for the 8x8 DVIKVM Dual Link Matrix is not currently implemented and will be available in a future release of the firmware...

Страница 82: ...erves the 5V state when the unit is restarted Power State The current power state is listed under the column titled 5 Volt Click these buttons to toggle the input power state Refresh Click to refresh...

Страница 83: ...oss to the matrix the 5V state for each input can be preserved Set the specified Power Status buttons see previous page and click the radio button next to ON Click the Update Power Lock State button t...

Страница 84: ...e cable for use with Gefen products Pin Color 1 Orange White 2 Orange 3 Green White 4 Blue 5 Blue White 6 Green 7 Brown White 8 Brown Cabling comes in stranded and solid core types Gefen recommends us...

Страница 85: ...following settings Baud rate 19200 Stop bits 1 Data bits 8 Flow control None 3 Type the command activebolo Two options will be provided To download the file DVI8x8 please type the command activebolo...

Страница 86: ...le corresponding to the boot loader which was activated In this first case the file should start with DVI8x8 11 Select Ymodem for the protocol 12 Press Send on the Send File dialog box 13 A message wi...

Страница 87: ...air flow as needed to maintain the recommended temperature inside the rack c Do not exceed maximum weight loads for the rack Install heavier equipment in the lower part of the rack to maintain stabili...

Страница 88: ...tors 8 3 5 mm mini stereo Audio Input Connectors 8 3 5 mm mini stereo Frequency Response 0 1dB 20Hz 100 kHz THD 0 002 20 kHz IR Extender 3 5 mm mini stereo RS 232 Interface DB 9 female IP Interface RJ...

Страница 89: ...Proof of sale may be required in order to claim warranty 2 Customers outside the US are responsible for shipping charges to and from Gefen 3 Copper cables are limited to a 30 day warranty and cables...

Страница 90: ...me of the author may not be used to endorse or promote products derived from this software without specific prior written permission THIS SOFTWARE IS PROVIDED BY THE AUTHOR AS IS AND ANY EXPRESS OR IM...

Страница 91: ......

Страница 92: ...Rev B4 Pb...

Отзывы: