4.
Turn on hot water.
Ensure that all taps in the
water distribution system,
including outside faucets,
dishwashers, shower heads,
washing machines,
connections to refrigerators,
toilets, etc. are open. Run
the water until you smell
the bleach and then close all
the tabs.
5 .DO NOT use water for
one hour.
6 .After one hour, open all
tabs and run the water for
about 10 minutes to make
sure that all the chlorine is
washed out. Keep the UV
system on during this time.
7. Once all the chlorine is flushed from the water distribution system,
and while the UV system remains on, shut off the water supply again and
re-install cartridges in the housing water filter.
8. Turn on the water supply again. Make sure you check the water for
leaks and contaminants!
NOTE
1.Ensure that the UV system controller is plugged during the entire
disinfection process.
2.The disinfection procedure results in a massive chlorine presence
in the water, far in excess of the 0.5 - 1.0 mg/L typically present in
municipally chlorinated water. While this is consistent with the
minimum 50 mg/L chlorine solution recommended for the
disinfection of the water distribution systems known to be
contaminated, DO NOT consume water until the system has been
fully flushed out.
9
www.geekpure.cc