GEDA
®
Rubbish Chute
Assembly and Operating Manual
Page 24 of 24
BL041GB Edition 05.2012
5.6
Installation on a flat roof
WARNING
When installing on a flat roof, the rubbish chute is installed at least two
metres away from the building edge. If this is not possible, appropriate
safety rails must be provided.
Push the flat-roof frame outwards but only so far that the cross-
connection still rests on the edge of the roof. The flat-roof frame must
not lie concavely. Use load-distributing substrate materials.
Counterweights (Item No.: 01912) place on the extension tubes
according to the assembly height.
The flat-roof frame consists
of two supporting tubes and
one cross-connector with a
safety guard.
Lay supporting tubes on the
flat roof accordingly. Install
cross-beam with safety
railing. Insert extension
tubes into the supporting
tubes and secure using
bolts.
Further assembly of the rubbish chute as described above.
5.7
Disassembly
The same regulations and safety instructions as described for assembly
apply for disassembly.
Disassembly is generally carried out in the reverse order to assembly.
Assembly height
Number of
counterweights
Bearing force "F"
Tubes
vertical
Tubes
deflected
downwards
up to 6 m
2 pcs
1.7 kN
----
up to 11 m
4 pcs
2.6 kN
----
up to 17 m
6 pcs
3.6 kN
5.5 kN
up to 22 m
8 pcs
4.5 kN
6.8 kN
up to 28 m
10 pcs
5.6 kN
8.3 kN
up to 33 m
12 pcs
6.5 kN
9.0 kN
up to 40 m
14 pcs
7.8 kN
9.8 kN