background image

 

GECMA.COMPONENTS GMBH 

WWW.GECMA.COM

 

TEL. +49 2237 6996-0    FAX -99 

MANUAL MI_PS2_B REV 1.3 EN.DOC  31.01.07         A. J.     

5

 

 

Safety Instructions 

General Safety Instructions 

The instructions stated in this chapter are to be followed accurately to ensure a safe and reliable 
operation. 

The license and the special conditions included in it are to be observed. 

Follow the national safety regulations and the accident prevention regulations. 

The installation is only to be performed by specialists. These specialist must be familiar with the 
characteristics of explosion-endangered facilities.  

Incorrect or inadmissible application as well as non-observance of the instructions of this operating 
manual make the guarantee void. 

Only use this device for the approved purpose.  

Conversions and modifications to the device are inadmissible. 

The housing is only to be opened by the company Gecma Components GmbH. 

Assembly 

The national assembly and installation regulations are to be observed. 

The generally accepted rules of engineering are to be observed. 

The entire equipment is to be connected and operated correctly and properly according to the 
applicable standards, guidelines and installation instructions.  

The housing is to be grounded via grounding equipment.  Grounding must be effected with a core cross section 
of at least 4mm².  

The device is only to be connected in a de-energized condition. 

The intrinsically safe line system with supply and signal lines has to be effected in such a way that no error must be 
considered between the individual circuits, see IEC 600-79-14, 12.2.2.8. 

When installing new components observe that all seals are in a flawless condition and function properly. 

Before putting the device into operation make sure that the device has been installed as prescribed and 
that the device and its wiring are not damaged. 

If the power supply of the device is not intrinsically safe, the license will become void and it must not be 
operated as an intrinsically safe device.  If the device was operated intrinsically safely with a low level of 
international protection (e.g. ib), it must not be operated afterwards in applications for a higher level of 
international protection (e.g. ia).  

Operation 

The device is only to be operated in an undamaged and clean condition. 

If the device has suffered any damages which might affect the international protection (e.g. cracks, holes 
or broken components) it must be taken out of service immediately. The device can only be put into 
operation again after the defect components have been exchanged. 

When the mouse is damaged, do not touch it any longer! Risk of injury! 

The devices (modules) may not be suspended impacts and/or frictions. High-energy load mechanisms at 

the control surface of the equipment (e.g. pneumatic particle transport) are to be excluded with the use. 

 
 

In the event of non-observance & non-compliance the stipulated explosion protection cannot be 

guaranteed and/or the guarantee will become void! 

Modifications require the written approval by the company GeCma Components GmbH. 

Содержание CHALLENGER Mi-PS2

Страница 1: ...GECMA COMPONENTS GMBH WWW GECMA COM TEL 49 2237 6996 0 FAX 99 MANUAL MI_PS2_B REV 1 3 EN DOC 31 01 07 A J 1 Manual Mouse Module CHALLENGER Mi PS2 Mi PS2 B...

Страница 2: ...operating device for the application in zone 0 zone 1 It is equipped with a PS 2 data interface for connection to an intrinsically safe data interface The Challenger Mouse PS2 consist of a silicon ma...

Страница 3: ...nd fastened from the inside via mounting clips which are evenly distributed over the external circumference of the keyboard housing in such a way that the module is tight fitting Pin Connections Pin c...

Страница 4: ...mensions see drawings International protection encl Front side IP66 NEMA 4X with expert installation Connection Mi PS2 Mi PS2 B K46 4 x 0 5 2 5 mm rigid flexible or connecting line Storage temperature...

Страница 5: ...with supply and signal lines has to be effected in such a way that no error must be considered between the individual circuits see IEC 600 79 14 12 2 2 8 When installing new components observe that al...