DIFFERENCES BETWEEN THE G201X AND G201 
 
The G201X is 100% backwards compatible with the G201 and G210. It has several new features and performance enhancements: 
 

1.)

 

STEP and DIRECTION is +3.3VDC and +5VDC compatible at 2.5mA 

2.)

 

Recirculate mode during STANDBY greatly reduces motor heating while stopped 

3.)

 

No external 470uF capacitor needed 

4.)

 

Power-on RESET 

5.)

 

Direction is clocked in on the active step pulse edge 

6.)

 

No internal jumpers, no current set resistor, DIP switch settings 

7.)

 

Low motor heating while stopped 

8.)

 

Universal step and direction COMMON 

 
G201X TERMINAL WIRING 
 
The G201X uses a 2-piece modular main connector. The connector is split in two pieces; terminals 1 through 6 (power supply and 
motor  leads)  and  terminals  7  through  12  (control  interface).  Each  can  be  removed  separately  by  pulling  the  connector  body 
upwards and off of the mating header pins on the G201X. The connectors must initially be removed to mount the G201X to a 
heatsink or chassis. 
 
TERMINAL 1 

Power Ground 

 

 

Connect the negative (black) lead of your power supply to this terminal. 

 
TERMINAL 2 

Power (+) 
Connect the positive (red) lead of your power supply to this terminal. It must be b18VDC to 
+80VDC. 

 
TERMINAL 3 

Motor Phase A 

 

 

Connect one end of your “Phase A” motor winding here. 

 
TERMINAL 4 

Motor Phase /A 

 

 

Connect the other end of your “Phase A” motor winding here. 

 
TERMINAL 5 

Motor Phase B 

 

 

Connect one end of your “Phase B” motor winding here. 

 
TERMINAL 6 

Motor Phase /B 

 

 

Connect the other end of your “Phase B” motor winding here. 

 
TERMINAL 7 

Disable 

 

 

This terminal will force the winding currents to zero when shorted to TERMINAL 12. 

 
TERMINAL 8 

Direction 

 

 

Connect the DIRECTION signal to this terminal. 

 
TERMINAL 9 

Step 

 

 

Connect the STEP signal to this terminal. 

 
TERMINAL 10 

Common 

 

 

Connect the controller’s +3.3VDC, +5VDC or GND to this terminal. 

 
TERMINAL 11 

Current Set (OPTIONAL) 

 

 

Connect one end of your current set resistor to this terminal. 

 
TERMINAL 12 

Current Set (OPTIONAL) 

 

 

Connect the other end of your current set resistor to this terminal. 

 

Содержание G201X

Страница 1: ...G201X G210X MANUAL STEP MOTOR DRIVE ...

Страница 2: ...A Power Dissipation 1 13 W Temperature 0 70 C Humidity 0 95 Motor Inductance 1 50 mH Input Frequency 0 200 kHz Step Pulse 0 Time COMMON 3 3V 5V 0 5 uS Step Pulse 1 Time COMMON 3 3V 5V 3 uS Step Pulse 0 Time COMMON GND 3 uS Step Pulse 1 Time COMMON GND 0 5 uS Direction Setup 0 uS Signal Voltage 3 3 5 VDC Weight 3 6 oz ...

Страница 3: ...ally be removed to mount the G201X to a heatsink or chassis TERMINAL 1 Power Ground Connect the negative black lead of your power supply to this terminal TERMINAL 2 Power Connect the positive red lead of your power supply to this terminal It must be between 18VDC to 80VDC TERMINAL 3 Motor Phase A Connect one end of your Phase A motor winding here TERMINAL 4 Motor Phase A Connect the other end of y...

Страница 4: ...500uH or greater but generally no more than 7mH A more accurate calculation of power supply voltage is to find your motor s inductance and put it into the following equation 32 mH inductance Power Supply Voltage If your motor has 2mH of inductance the equation would look as follows 32 2 45 12V MOTOR CONNECTION TERMINAL 3 Phase A Connect one motor winding to this terminal TERMINAL 4 Phase A Connect...

Страница 5: ...ic 0 time is 5uS while the minimum logic 1 time is 3uS with 3 3V 5V connected on the COMMON terminal The minimum logic 0 time is 3uS while the minimum logic 1 time is 0 5uS when connected to GND on the COMMON terminal Microstepping occurs on the falling edge of the step input when COMMON is a positive voltage and on the rising edge when COMMON is connected to GND and on the rising edge when connec...

Страница 6: ... SW2 SW3 SW4 and SW5 to the ON position 2 Automatic Current Standby The G201X reduces motor phase current to 70 of the set value when the motor is stopped This can reduce motor heating up to half while the motor is not moving If enabled this reduction occurs 1 second after the last step pulse is sent to the drive Full current is restored immediately upon resumption of step pulses SW9 enables this ...

Страница 7: ...OPTION SET SWITCHES ...

Страница 8: ... It is recommended that needle nose pliers or tweezers be used to adjust the jumper settings The power to the G210X must be turned off before any adjustment is to be made on the step pulse multiplier METHOD OF OPERATION FOR STEP PULSE MULTIPLIER The G901X step pulse multiplier still allows all of the benefits of microstepping at low speeds and full stepping at high speeds that the G201X has The st...

Страница 9: ...IVE INC PRODUCTS ARE NOT DESIGNED AUTHORIZED OR WARRANTED TO BE SUITABLE FOR USE IN LIFE SUPPORT DEVICES OR OTHER CRITICAL APPLICATIONS INCLUSION OF GECKODRIVE INC PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO BE FULLY AT THE PURCHASER S OWN RISK In order to minimize risks associated with the purchaser s application adequate design and operating safeguards must be provided by the purchaser to min...

Отзывы: