8

Program menu

The program menu is accessible by holding down the 

Light

 key for 5 seconds� In the program menu the following 

parameters can be set:  clock, filter or purge cycles, economy 
mode and temperature units� While in the program menu, 
use the 

Up

 or 

Down

 key to adjust the parameters and use 

the 

Light

 key to jump to the next parameter� The changes will 

be saved after the confirmation of the last parameter only�  
If there is no action taken for 10 seconds, the system will exit 
the program menu without saving any changes�

Setting the clock

Enter the program menu by holding down the 

Light

 key 

for 5 seconds� The display will show the current clock setting 
with the hour flashing�

Depending on factory settings your system may be set 
to 24-hour time or 12-hour time�

Setting the hour: Use the arrow keys to adjust the hour� Press 
the 

Light

 key to jump to the next parameter, the minutes�

Setting the minutes: Use the arrow keys to adjust the 
minutes� Press the 

Light

 key to jump to the next parameter, 

the filter or purge start time (FS)�

Programming the filter/ purge cycles

Depending on system configuration your spa will 
perform either a filter or a purge cycle� The filter cycle 
menu consists of the following parameters: the start time 
(FS), the duration (Fd) and the frequency (FF)� The purge 
cycle menu consists of the following parameters: the start 
time (FS) and the frequency (FF)� 

A filter cycle consists of starting all the pumps and blower 
in high speed for 1 minute (purge step) then, the pump 
associated with the filter will run in low speed for the 
remaining duration of the filter cycle (clean step)� 

A purge cycle is used when the spa is equipped with a  
24 hour circulation pump which provides a continuous 
clean step� It consists of starting all the pumps and blower 
in high speed for 1 minute� 

Programming steps

Содержание in.k300

Страница 1: ...ns Qu bec Qc G2E 5W6 Canada 1 800 78 GECKO www geckoalliance com Printed in Canada 9919 101218 D Rev 02 2018 Groupe Gecko Alliance Inc 2018 All trademarks or registered trademarks are the property of...

Страница 2: ...Off Mode 7 Programming steps 8 Program menu 8 Setting the clock 8 Programming the filter purge cycles 8 Setting filter or purge cycle start time 9 Setting filter cycle duration 9 Setting filter or pu...

Страница 3: ...ETAILS HAZARDOUS CONDITION A CONDITION THAT IS POTENTIALLY DAMAGING AND OR DANGEROUS TO THE OPERATOR OR SURROUNDINGS THIS INCLUDES BUT IS NOT LIMITED TO FIRE FLOODING OR OTHER WATER DAMAGE DIELECTRIC...

Страница 4: ...nough to be seen in day simple enough to use in the middle of the night affordable yet solidly built Item in k300 Static LCD size as measured diagonally 1 5 Optional mounting with wing nuts and spacer...

Страница 5: ...e installation surface and peel the adhesive gasket from the back of the keypad Insert keypad and align it correctly then ensure it is properly glued by gently pressing evenly on the entire surface Ga...

Страница 6: ...5 Drilling template 36 58 mm 144 02 mm 131 32 mm R 6 35 mm R 6 35 mm...

Страница 7: ...00 Main keypad in k300 in xe in xm 2 To connect the in k300 keypad simply insert its in link connector into the appropriate keypad connector of the pack enclosure as illustrated in ye in yt To connect...

Страница 8: ...red temperature The set point icon will appear at the top of the screen After 3 seconds without any change to the set temperature value the keypad will resume the normal display Off Mode Pressing Pump...

Страница 9: ...s to adjust the hour Press the Light key to jump to the next parameter the minutes Setting the minutes Use the arrow keys to adjust the minutes Press the Light key to jump to the next parameter the fi...

Страница 10: ...quency FF 0 no filtration 24 continuous filtration It is not recommended to set this to 0 Setting economy mode This mode allows you to lower the temperature set point of the spa by 20 F 11 C during a...

Страница 11: ...hes when the purge is active Water temperature regulation Every 15 to 90 minutes the pump will run to ensure accurate water temperature readings as well as avoid heater activation in dry conditions Af...

Страница 12: ...in xm2 in therm incompatible SC ER Learning mode error F1 in xm2 Fuse 1 is blown F2 in xm2 Fuse 2 is blown F3 in xm2 Fuse 3 is blown Hr Danger Thermal fuse error UPL The spa pack does not have valid...

Страница 13: ...tal Operating temperature 68 F 20 C to 149 F 65 C Storage temperature 22 F 30 C to 185 F 85 C Humidity Up to 70 condensing Water ingress protection IPX 5 Mechanical Weight 0 69 lb 313 g Dimensions W x...

Страница 14: ...ns Qu bec Qc G2E 5W6 Canada 1 800 78 GECKO www geckoalliance com Printed in Canada 9919 101218 D Rev 02 2018 Groupe Gecko Alliance Inc 2018 All trademarks or registered trademarks are the property of...

Отзывы: