GENERAL
•
Your Aqua-Flo by Gecko pump has been quality built and
engineered to give maximum efficiency under normal
working conditions. Consult the manufacturer for any other
applications.
•
Below you have the maximum total head by pump family
Flo-Master® XP3: 082, 083:
9.4m
Flo-Master® XP2e: 052, 053:
15.7m
Flo-Master® XP2: 070, 071:
16.5m
Circ-Master HP/CP/XP: 024, 029, 063: 4m
LOCATION OF PUMP
•
For optimal pump performance, locate the system as close
to the water source as possible. Provide adequate access
around the pump for inspections and maintenance.
•
This pump was designed for below water level (flooded
suction) applications. Make sure the pump is installed at a
level that will allow the pump casing (volute) to be
completely filled with water.
PLUMBING AND FITTINGS
•
Two compression fittings are included with your pump for
ease of installation and maintenance. Make sure the fittings
are correctly aligned with pump connections to allow the
o-ring to ensure proper sealing.
Hand tighten only. Do not
use a wrench to tighten fittings.
•
Avoid excessive tightening of pipe or fittings in any areas
where threaded connections are used.
•
For Aqua-Flo by Gecko's compression fittings DO NOT
USE any Thread Seal Tape (PTFE tape), Teflon
Quick-Seal Thread Sealing Compound, Plasto-Joint Stik
or any other sealants.
•
For NPT threaded connections
(and ONLY National Pipe
Thread threaded connections)
use any Thread Seal Tape
(PTFE tape), Teflon Quick-Seal Thread Sealing Compound,
Plasto-Joint Stik or any other sealants formulated specifical-
ly for plastics.
STARTING & PRIMING PUMP
•
Do not run unit dry.
Always be certain that the pump
casing is filled with water before starting the unit. Allow a
reasonable amount of time for priming.
MAINTENANCE
•
Keep the motor clean. Ensure that all openings are free
from debris and obstructions. Over a period of time, the
impeller seal may become damaged or worn and must
be replaced.
WINTERIZATION
•
To prevent damage during freezing conditions, disconnect
all electrical power. Drain thoroughly and clean out any
debris. Protect pump and motor from elements by covering
or, if possible, store in a dry, well ventilated room.
INSTALLATION & OPERATING INSTRUCTIONS
Bonding wire − Upon installation of the pump, the motor must be bonded with (no smaller than) a 8.4 mm² (no.8 awg) solid copper conductor
per national electric code. The connection should be from the accessible wire connector on the motor to all metal parts of the swimming pool,
spa or hot tub structure and to all electrical equipment, metal conduit and metal piping within 1.5m (5 feet) of the inside walls of the swimming
pool, spa or hot tub, when the motor is installed within 1.5m (5 feet) of the inside walls of the swimming pool, spa or hot tub.
REMINDER: FOR ELECTRICAL CONNECTIONS, SEE WIRING DIAGRAM ON MOTOR RATING PLATE.
GECKO ALLIANCE GROUP
450 des Canetons, Québec, QC, Canada, G2E 5W6
1.800.78.GECKO
going strongly against the flow
www.geckoalliance.com
www.geckopumps.com
2017 © aqua-flo by gecko # 9919-101540-A
pumps for small to swim spas
Aqua-Flo by Gecko
pumps for small to swim spas