BromiCharge™ level monitoring

        Water must be circulating through 

the in.clear™ cell in order for the 

Diagnostic Mode to work. If no water 

is circulating through the in.clear™ 

unit, a FLO message will appear on the 

keypad display. Make sure the pump is 

circulating water through the in.clear™.

 

Be aware that the gauge will move 

according to BromiCharge™ level. 

Make sure your water temperature is at 

least 32° C (90° F).

troubleshooting

Low BromiCharge™ Error

Low BromiCharge™ Error 

(Err) occurs when the 

BromiCharge™ level is too 

low. The lo LED indicator will 

blink when the error is present. 

The in.clear™ system will not 

generate bromine until the 

Low BromiCharge™ Error (Err) is 

cleared.

To clear the Low BromiCharge™ 

error (Err), add BromiCharge™ 

to the spa water. Let water 

circulate for 5 minutes. Activate 

diagnostic mode and add more 

BromiCharge™ until gauge is 

back in the green zone. Exit 

diagnostic mode.

Low BromiCharge™ 
Warning 

Low BromiCharge™ Warning 

(Lo) indicates the need to add 

BromiCharge™ to the spa water.  

In Diagnostic Mode, add 

BromiCharge™ to the water 

until the gauge reaches the 

green zone to clear a Low 

BromiCharge™ Warning (Lo).

         If after adding 

BromiCharge™ the Low 

BromiCharge™ Warning (Lo) 

or Low BromiCharge™ Error 

(Err) still occurs it could be the 

result of:

• calcification of the electrolytic 

plates;

• airlocks trapped in the 

in.clear™ unit or insufficient 

flow;

• internal pressure switch 

problem.

High BromiCharge™ 
Warning 

High BromiCharge™ Warning 

(Hi) occurs when too much 

BromiCharge™ is present in 

the water or there is a high 

TDS level (hardness, alkalinity, 

organic compounds, ...).

To clear a High BromiCharge™ 

Warning, readjust the 

BromiCharge™ content of your 

water in Diagnostic Mode, into 

green zone by draining some 

water from your spa and adding 

fresh water.

BromiCharge™ gauge (LEDs)

In Diagnostic mode, the BromiCharge™ gauge (LEDs) indicates the 

approximate BromiCharge™ level of your spa water. 

When adding BromiCharge™, the gauge indicator will gradually 

shift to the right. When adding clean water to the spa the indicator 

will shift to the left. In order to acheive the proper level, start pumps 

and add 454 Grams (1 Pound) at a time and always allow 5 minutes 

for the gauge to react before adding more BromiCharge™.

The green zone in the center area of the gauge and a 12.0 value 

should be targeted for optimal performance.

BromiCharge™ gauge

Содержание Aeware 3 in.clear

Страница 1: ...in ye spa pack general operation pages 2 7 in k450 keypad operation pages 9 15 in clear water sanitation system operation pages 16 43 in stream sound system operation pages 44 47...

Страница 2: ...IN THIS UNIT TO PREVENT ELECTRIC SHOCK HAZARD AND OR WATER DAMAGE TO THIS CONTROL ALL UNUSED RECEPTACLES MUST HAVE A DUMMY PLUG THIS CONTROLLER MUST NOT BE INSTALLED IN PROXIMITY OF HIGHLY FLAMMABLE M...

Страница 3: ...LECTRICAL CODE IN EFFECT AT THE TIME OF THE INSTALLATION Electrical wiring North American model Lamp test All the segments and LEDs are lighting up Software revision Revision of the software Low level...

Страница 4: ...d to ensure proper functioning of the system Both the error code and the water temperature are alternatively displayed Allerrorscodeswillbedisplayed onthe keypad display FLO The system did not detect...

Страница 5: ...9 in k450 overview in k450 user instructions and functions...

Страница 6: ...element is cooling down or 3 not enough current available to start heater Light icon The Light icon lights up when the light is on The icon s number of rays is proportional to the light s intensity Sm...

Страница 7: ...ON Third press Pump 3 OFF Blower ON Fourth press Pump 3 OFF Blower OFF A built in timer automatically turns blower off after a 20 minute period unless blower has been manually deactivated first functi...

Страница 8: ...emperature reading if required the system automatically turns the heater on to reach and maintain water temperature at Set Point Cooldown Afterheatingthe spawaterto the desired Set Point the heaterist...

Страница 9: ...17 16 in clear in clear brominebasedwatersanitationsystem user instructions and functions instruction video www gecko com inclear...

Страница 10: ...rs should always shower before entering a spa warnings Warnings Important safety instructions For Canada in clear must only be used with Sodium Bromide such as BromiCharge scheduled or registered unde...

Страница 11: ...de The primary function of the Maintenance Mode is to keep the bromine bank levels at a stable and acceptable range when the spa is not being used Maintenance Mode is the everyday mode and is automati...

Страница 12: ...he plumbing even if the spa is brand new in clear getting started 3 Adjusting water chemistry in the spa Proper chemical maintenance of a spa is essential for the health of bathers Maintaining the qua...

Страница 13: ...until you are able to stabilize your bromine level between 3 and 5 PPM Do NOT increase decrease maintenance level in steps greater than 2 Setting the maintenance level to a value that s too high can c...

Страница 14: ...e 8 possible levels available with the Boost Mode As a rule of thumb the Boost level corresponds to the number of bathers using the spa Set the Boost level by using the up and down arrow to select the...

Страница 15: ...miCharge to the water See details next page Never adjust the main tenance level of your in clear without allowing at least 24 hours following the end of the Boost period Boost cycles allow the residua...

Страница 16: ...il the gauge reaches the green zone to clear a Low BromiCharge Warning Lo If after adding BromiCharge the Low BromiCharge Warning Lo or Low BromiCharge Error Err still occurs it could be the result of...

Страница 17: ...irculating properly to the cell Make sure water chemistry is in balance refer to section 3 Adjusting water chemistry in the spa for more details Test your spa water for phosphate to make sure there is...

Страница 18: ...substances contained in a liquid which are present in a molecular ionized or micro granular colloidal sol suspended form pH pH potential hydrogen is a measure of the acidity or basicity of a solution...

Страница 19: ...r muriatic acid Install the rubber washer and the plastic nut on the threaded end of the cell Tighten plastic nut firmly Place the cell vertically with the cap end down into a plastic 19 liters 5 U S...

Страница 20: ...m Hardness CaCo 125 to 200 adjust if necessary Alkalinity 80 to 90 adjust if necessary pH 7 0 to 7 8 adjust if necessary Adjust the above factors to meet optimum range values user guide for BromiCharg...

Страница 21: ...GENERATOR on to build the bromine bank and bring it within 2 5 PPM range THE RECOMMENDED BROMINE LEVEL IS BETWEEN 2 5 PPM user guide for BromiCharge user guide for BromiCharge DIRECTIONS FOR USE For S...

Страница 22: ...PM Purchasing a TDS meter at any spa pool store can do this or they will check it for you If you are adding water often beyond what has evaporated or splashed out then you may have a leak If you have...

Страница 23: ...t work when AUX is selected as the source Turning power on off When connected to a power source the unit will automatically be ON Pressing and holding the Play Pause button will turn the unit off Once...

Страница 24: ...g 2 In these settings turn Bluetooth on if it is not already 3 Choose Gecko in stream from the list of available devices 4 When prompted enter 5555 as the password Your device should now be paired wit...

Страница 25: ......

Отзывы: