31
30
in.clear
in.clear
BromiCharge™ level monitoring
Water must be circulating through
the in.clear™ cell in order for the
Diagnostic Mode to work. If no water
is circulating through the in.clear™
unit, a FLO message will appear on the
keypad display. Make sure the pump is
circulating water through the in.clear™.
Be aware that the gauge will move
according to BromiCharge™ level.
Make sure your water temperature is at
least 32° C (90° F).
troubleshooting
Low BromiCharge™ Error
Low BromiCharge™ Error
(Err) occurs when the
BromiCharge™ level is too
low. The lo LED indicator will
blink when the error is present.
The in.clear™ system will not
generate bromine until the
Low BromiCharge™ Error (Err) is
cleared.
To clear the Low BromiCharge™
error (Err), add BromiCharge™
to the spa water. Let water
circulate for 5 minutes. Activate
diagnostic mode and add more
BromiCharge™ until gauge is
back in the green zone. Exit
diagnostic mode.
Low BromiCharge™
Warning
Low BromiCharge™ Warning
(Lo) indicates the need to add
BromiCharge™ to the spa water.
In Diagnostic Mode, add
BromiCharge™ to the water
until the gauge reaches the
green zone to clear a Low
BromiCharge™ Warning (Lo).
If after adding
BromiCharge™ the Low
BromiCharge™ Warning (Lo)
or Low BromiCharge™ Error
(Err) still occurs it could be the
result of:
• calcification of the electrolytic
plates;
• airlocks trapped in the
in.clear™ unit or insufficient
flow;
• internal pressure switch
problem.
High BromiCharge™
Warning
High BromiCharge™ Warning
(Hi) occurs when too much
BromiCharge™ is present in
the water or there is a high
TDS level (hardness, alkalinity,
organic compounds, ...).
To clear a High BromiCharge™
Warning, readjust the
BromiCharge™ content of your
water in Diagnostic Mode, into
green zone by draining some
water from your spa and adding
fresh water.
BromiCharge™ gauge (LEDs)
In Diagnostic mode, the BromiCharge™ gauge (LEDs) indicates the
approximate BromiCharge™ level of your spa water.
When adding BromiCharge™, the gauge indicator will gradually
shift to the right. When adding clean water to the spa the indicator
will shift to the left. In order to acheive the proper level, start pumps
and add 454 Grams (1 Pound) at a time and always allow 5 minutes
for the gauge to react before adding more BromiCharge™.
The green zone in the center area of the gauge and a 12.0 value
should be targeted for optimal performance.
BromiCharge™ gauge