10
CAUTION
Do not install the unit in a place where flammable gas leak can occur
All plumbing connections should be carried out as per the instructions in this manual
Failure to do so could result in water damage to property
Avoid contact with the fan when the unit is operating as this will cause serious injury
Ensure the intemp is correctly grounded to earth with the power cable
Locating the in.temp
The intemp should NOT be installed in an airtight location or confined space, such as a basement or garage
The intemp requires good air ventilation It will discharge cold air when it is heating and hot air when it is
cooling, and its efficiency depends on its ability to draw normal ambient temperature air and discharge the
cold or hot air well away from the unit It is recommended to install the intemp away from any other home
appliances, to avoid the chance of electromagnetic interference Please refer to the "Air space requirements"
section of this manual
The unit should be located on a solid flat surface with a slight rearward slope Ensure 3 meters (9 feet) of free air flow to
the discharge panel and 1 meter (3 feet) to the inlet panel as well as free airflow to all sides of the unit Ensure adequate
access for maintenance purposes
In cold climates, the intemp should be installed at least 46 cm (18'') above the ground level on an open metal frame
in order to prevent the accumulation of ice at the base of the unit caused by condensation Your intemp specialist may
recommend a dedicated frame rusted proof See also recommendations in the Condensation section further
Air space requirements
Installation
0,5 m (20")
3 m (9')
1 m (3')
0,5 m (20")
*
Air inlet
Air outlet
* Top clearance is only a recommendation to ease service.