10

  

CAUTION

 

 

Do not install the unit in a place where flammable gas leak can occur

 

All plumbing connections should be carried out as per the instructions in this manual 

 

Failure to do so could result in water damage to property

 

Avoid contact with the fan when the unit is operating as this will cause serious injury

 
 

Ensure the intemp is correctly grounded to earth with the power cable

Locating the in.temp

  The intemp should NOT be installed in an airtight location or confined space, such as a basement or garage  

 

The intemp requires good air ventilation It will discharge cold air when it is heating and hot air when it is  

 

cooling, and its efficiency depends on its ability to draw normal ambient temperature air and discharge the  

 

cold or hot air well away from the unit It is recommended to install the intemp away from any other home  

 

appliances, to avoid the chance of electromagnetic interference Please refer to the "Air space requirements"  

 

section of this manual

The unit should be located on a solid flat surface with a slight rearward slope Ensure 3 meters (9 feet) of free air flow to 
the discharge panel and 1 meter (3 feet) to the inlet panel as well as free airflow to all sides of the unit Ensure adequate 
access for maintenance purposes

In cold climates, the intemp should be installed at least 46 cm (18'') above the ground level on an open metal frame 
in order to prevent the accumulation of ice at the base of the unit caused by condensation Your intemp specialist may 
recommend a dedicated frame rusted proof See also recommendations in the Condensation section further

Air space requirements

Installation

0,5 m (20")

3 m (9')

1 m (3')

0,5 m (20")

*

Air inlet

Air outlet

* Top clearance is only a recommendation to ease service.

Содержание 0615-807000

Страница 1: ...com Printed in Canada 9919 101640 A Rev 10 2019 Groupe Gecko Alliance inc 2019 All trademarks or registered trademarks are the property of their respective owners Plug and play solution Benefit from e...

Страница 2: ...ction 5 Overview 7 in temp overview 7 Box content 7 in temp dimensions 8 Exploded view 8 Connections 9 Installation 10 Operating modes 12 Maintenance 13 Steps to winterize your in temp 14 Troubleshoot...

Страница 3: ...NS FOR COMPATIBILITY DO NOT INSTALL NEAR ANY HEAT SOURCES CLEARANCE AND MINIMUM DISTANCE BETWEEN THE VARIOUS PARTS OF THE APPLIANCE AND THE SURROUNDING STRUCTURE ARE NOT SPECIFIED AS LONG AS THEY ARE...

Страница 4: ...US DO NOT USE FOAM TO ISOLATE THE UNIT TURN POWER OFF BEFORE MODIFYING ANY CABLE CONNECTION IN THIS UNIT TURN POWER OFF BEFORE CLEANING OR SERVICING THIS UNIT PRODUCT MUST BE DISPOSED OF SEPARATELY FR...

Страница 5: ......

Страница 6: ...ctly from the spa control Are you looking for the most energy efficient form of heating water Our in temp is the perfect solution Air sourced heat pumps will allow you to save up to 75 energy consumpt...

Страница 7: ...Carbon Emissions Titanium heat exchanger The advanced titanium heat exchanger guarantees a longer life span free of corrosion It can be used with all types of water treatment including chlorine iodin...

Страница 8: ...ord euro 14 3 AWG 5 meter 16 feet pre installed Optional sold separately 9920 401528 Heat pump communication cable 10 meter 33 feet 9920 401530 Heat pump power cord euro 14 3 AWG 10 meter 33 feet Box...

Страница 9: ...assembly Front panel Compressor B F E A G H C D B F E A G H C D B F E A G H C D in temp dimensions Gecko 5kW Gecko 7 5kW A 555 mm 21 85 in 661 mm 26 02 in B 794 mm 31 26 in 902 mm 35 51 in C 395 mm 1...

Страница 10: ...ries when the in temp or a different heat pump is not powered by the spa control set the heat pump current to zero 0 through your spa user interface Terminal box The terminal box is located behind the...

Страница 11: ...m the unit It is recommended to install the in temp away from any other home appliances to avoid the chance of electromagnetic interference Please refer to the Air space requirements section of this m...

Страница 12: ...ne salt etc the bypass must be installed before the water treatment with a check valve between the bypass and water treatment system Condensation The air drawn into the in temp is strongly cooled by t...

Страница 13: ...both Smart Heat and Cool modes and has the ability to select the proper Heat or Cool mode automatically according to the water temperature The heating element is activated only if there is a large te...

Страница 14: ...d condenser outflow should be clear of all obstructions leaves twigs etc before each new heating season These can be manually removed using compressed air or by flushing with clean water It may be nec...

Страница 15: ...out with air to ensure no water is left inside A compressed airline should be placed into the water outlet line to blow air through the unit Loosely reconnect the plumbing connection and drain plug to...

Страница 16: ...P18 Water outlet temperature sensor failure HP42 System 1 high pressure protection HP46 System 1 low pressure protection HP41 Water flow protection HP01 System 1 exhaust temperature sensor failure HP1...

Страница 17: ...Power input max 1 29 kW 1 91 kW 1 6 kW 2 3 kW Rated Current1 3 9 A 5 49 A 5 27 A 6 32 A Max Current1 6 07 A 8 67 A 7 5 A 9 6 A Communication Supply 10 12 Vdc 80mA 10 12 Vdc 80mA Performances CE model...

Страница 18: ...com Printed in Canada 9919 101640 A Rev 10 2019 Groupe Gecko Alliance inc 2019 All trademarks or registered trademarks are the property of their respective owners Plug and play solution Benefit from e...

Отзывы: