Gecko 0608-521033 Скачать руководство пользователя страница 14

13

Heat Mode Operations

4- BOTH (Both systems all at once)

Use this mode for swim spas or large spas, which have bigger needs of energy to keep the water temperature at the 
desired set point  

The spa control system will always use the external heating system AND the internal heater simultaneously to regulate 
the water temperature; they are both activated or deactivated at the same time

*This mode can be set with your intouch 2 app on a mobile device without the need to open the spa skirt to change the 
jumper setting on the ingrid

5- SMART (Energy savings)

Use this mode for a better energy saving purpose, combined with a maximum water temperature regulation efficiency 
The spa control system will always use the external heating system to regulate the water temperature If the temperature 
falls too far below your set point (-25°F), the internal heater will be activated to help your external heating system reach 
the set point 

Once the temperature is within 15°F from set point, the internal heater is deactivated and the external heating system 
takes all control of the water regulation again

*This mode can be set with your intouch 2 app on a mobile device without the need to open the spa skirt to change the 
jumper setting on the ingrid 

Содержание 0608-521033

Страница 1: ...da 9919 101532 B Rev 11 2017 Groupe Gecko Alliance inc 2017 All trademarks or registered trademarks are the property of their respective owners Select use and synchronize alternative heat sources Bene...

Страница 2: ...grid dimensions 6 OEM installation 6 Connections 7 Installation 9 Installation with external heat pump or gas heater 9 Installation with a heat exchange unit 10 Heat Mode Operations 11 in k110 and Acc...

Страница 3: ...N THE VARIOUS PARTS OF THE APPLIANCE AND THE SURROUNDING STRUCTURE ARE NOT SPECIFIED AS LONG AS THEY ARE SUFFICIENT SO THAT THE AMBIENT TEMPERATURE AROUND THE APPARATUS DOES NOT EXCEED 140 F 60 C ONLY...

Страница 4: ...VICING OR MODIFYING ANY CABLE CONNECTIONS IN THIS UNIT IN GRID ENCLOSURE SHALL BE LOCATED ABOVE THE FLOOD ZONE WHERE IT S UNLIKELY TO BE SUBMERGED IN THE EVENT THE SPA IS OVERFILLED OR SIMILAR ABNORMA...

Страница 5: ......

Страница 6: ...ng sources Connected to the CO port of your spa control system in grid will act as a dispatcher of external heating sources such as your heat pump or your central house heating system With in grid you...

Страница 7: ...s unit is connected to an in ye or a in yt spa control system We recommend that you install the unit with 8 pan head screws The unit must be installed in an upright position as illustrated Fastening b...

Страница 8: ...te properly in grid connection with accessories If you have a lot of accessories the in link cable of the in grid with 4 single button switches and a CO port can also be connected to any CO port of an...

Страница 9: ...ections The cable must be passed through the already installed watertight grommet Use wire gage between AWG 24 and AWG 16 Use cable with round jacket suitable for the watertight grommet Diameter shoul...

Страница 10: ...a control system heater as illustrated above The unit must be installed after your spa control system as illustrated above You need to be sure your pump heater or gas heater is set to the maximum set...

Страница 11: ...your Y series spa control system needs a minimum of 20 GPM all the time Make sure to always connect your heat exchange unit in the same water pipe filter of your Y series spa control system heater The...

Страница 12: ...l be closed if the external heating system is activated Otherwise the relay contacts are open Your desired heat mode must be set by adding a jumper on one of the five 5 different positions Note Your h...

Страница 13: ...it will be easier to set your preferred heating mode back once the external heating system is available 3 EXT External Use this mode for a maximum energy saving purpose The spa control system will onl...

Страница 14: ...the in grid 5 SMART Energy savings Use this mode for a better energy saving purpose combined with a maximum water temperature regulation efficiency The spa control system will always use the external...

Страница 15: ...output connectors available at the front The AC jumper line goes from top to bottom and the AC connector line goes from left to right e g If your first jumper on your AC selector line is P2 it will b...

Страница 16: ...e Accessory AC jumper Settings AC 1 P1 AC 2 P2 AC 3 LST AC 4 L Heat Mode SMART Accessory AC jumper Settings AC 1 P1 AC 2 P2 AC 3 P3 AC 4 P4 AC 5 P5 Heat Mode DIS Disable in grid 4 AC and CO model Part...

Страница 17: ...nking light Spa control system not detected not compatible or in Disable mode if one of your single switches doesn t operate properly Solid light Spa control system detected No light Power Off Diagnos...

Страница 18: ...to 185 F 85 C Humidity 70 Max Water resistance IPX5 Mechanical Weight 0 85 lb Dimensions W x H x D 5 50 x 4 48 x 1 84 Compatibility in ye and in yt spa control systems with appropriate software revisi...

Страница 19: ...da 9919 101532 B Rev 11 2017 Groupe Gecko Alliance inc 2017 All trademarks or registered trademarks are the property of their respective owners Select use and synchronize alternative heat sources Bene...

Отзывы: