OPERATION WITH NORMALLY

CLOSED (N.C.) VALVE

OPERATION TEST

Before carrying out the operation test, open the cover under the
three LED lights (Fig. 10) with a flat-headed screwdriver.

Fig.10

When this is done, it is possible to test operation of the instrument
by pressing and holding the little button on the 

Sensor module

(Fig. 11) for at least 2 seconds; all the LEDs turn on and the buzzer
and relay output are activated for 5 seconds.

Fig.11

You will then need to re-engage the electric valve connected to the
output of the gas detector (if present).

Fig.9

ROUTINE TESTING

You are advised to ask the installer to give the detector a general
test at least once a year.

IMPORTANT: Do not use pure gas, such as that in a lighter,
directly on the sensor since the sensor could be irremediably
damaged.

ELECTRICAL CONNECTION WITH SEVERAL

DETECTORS:

Connection of two detectors with a single electric valve (Fig. 8-9)
is shown in the diagrams below. It is possible to connect more
than two detectors, repeating the same connections.

OPERATION WITH NORMALLY

OPEN (N.O.) VALVE

Fig. 6 Example of jumper with N.C. contact (

CONSTANT OUTPUT

)

and 

Normally Open electric valve

 with load at 230Vac.

  

    JUMPER WITH N.C.

(CONSTANT OUTPUT)

Fig.7 Esempio jumper su N.C. (

USCITA COSTANTE

)  ed elettrovalvola

Normalmente Chiusa

 con carico a 230Vac.

Aspiratore, Ventilatore, Sirene...etc. .a 230Vac

Fig.8

N.O. MANUAL RESET VALVE

Fig.6

Extractor, Fan, Buzzer, etc. at 230Vac

N.C. MANUAL RESET VALVE

TO BE COMPILED BY THE INSTALLER:

Date of installation ________________________________________

Date of replacement ______________________________________

Attention: the detector must be replaced 15 years after the
date of installation on this voucher

Site of installation _________________________________________

Serial number (s.n.) _______________________________________
(Written on the inside of the plastic container).

Date of initial replacement of sensor module:____________________

Date of second replacement of sensor module:__________________

Attention: the entire detector must be replaced five years
after second replacement of the sensor module.