background image

Troubleshooting

The operator can perform the following measures to rectify malfunctions. → See operation manual
966.933.00.0 (mains operation) and 966.934.00.0 (battery operation and self-sustaining).

• Restart the urinal flush control
• Set the flush time
• Optimise the detection distance
• Clean the basket filter
• Replace the batteries
• Charge the rechargeable battery of the self-sustaining power supply

Malfunction

Cause

Action

Incorrect flushes (too soon, too late,
unwanted)

Detection distance not set
correctly

▶ Optimise the detection distance.

→ See operation manual.

IR window is dirty or wet

▶ Clean or dry the IR window.

IR window scratched

▶ Replace the control electronics.

Water is running continuously into the
urinal ceramic.

Software fault

▶ Restart the urinal flush control. →

See operation manual.

Technical fault

▶ Replace the control electronics or

the solenoid valve.

Flushing out of the urinal ceramic is
inadequate.

Flush time set incorrectly

▶ Set flush time. → See operation

manual.

Flush volume is inadequate.

Basket filter in solenoid
valve blocked

▶ Clean the basket filter. → See

operation manual.

Water pressure reducing
valve blocked

▶ Replace the water pressure

reducing valve.

No flush actuation

Network failure

▶ Check the power supply.

Battery warning level 1
(4 short signal tones upon entering the
detection range)

Batteries dead
Rechargeable battery
empty

▶ Replace the batteries.
▶ Charge the rechargeable battery

of the self-sustaining power
supply.

Battery warning level 2
(no flush actuation, 2 short signal tones
every 30 seconds)

Battery warning level 3
(no flush actuation, no signal tone)

54043198642350731 © 01-2021
967.135.00.0(05)

7

Содержание Preda 116.072.00.1

Страница 1: ...MAINTENANCE MANUAL...

Страница 2: ......

Страница 3: ...nance performed by skilled persons 8 Replacing the control electronics 9 Replacing the solenoid valve 11 Replacing the water pressure reducing valve 15 Making settings using Geberit Service Handy 18 S...

Страница 4: ...ith integrated flush control self sustaining Intended use Urinals allow for urinating while standing up These urinals are designed to be operated using a flush Use for any other purpose is deemed impr...

Страница 5: ...ead 2 Urinal ceramic 3 Urinal trap 4 Water pressure reducing valve 5 Solenoid valve with basket filter 6 Generator only for self sustaining power supply 7 Urinal flush control with control electronics...

Страница 6: ...erature 20 70 C 20 70 C 20 70 C Flow rate at 1 bar with flow regulator 0 18 l s 0 18 l s 0 18 l s Flush time factory setting 7 s 7 s 7 s Flush time adjustment range 1 15 s 1 15 s 1 15 s 1 Battery serv...

Страница 7: ...ceramic Software fault Restart the urinal flush control See operation manual Technical fault Replace the control electronics or the solenoid valve Flushing out of the urinal ceramic is inadequate Flus...

Страница 8: ...e Clean the urinal ceramic Clean and replace the spray head Replace the urinal trap Set the flush time Optimise the detection distance Clean the basket filter Replace the batteries Charge the recharge...

Страница 9: ...electronics 1 Release the protection flap 2 Open the protection flap 3 Remove the urinal flush control 4 Open the urinal flush control cover 5 Disconnect the power supply cable 54043198642350731 01 2...

Страница 10: ...Remove the defective control electronics 8 Insert the new control electronics 9 Connect the cable for the solenoid valve 10 Connect the power supply cable 11 Close the urinal flush control cover 10 54...

Страница 11: ...nal flush control 13 Close the protection flap Result The urinal is ready for operation Replacing the solenoid valve 1 Release the protection flap 2 Open the protection flap 54043198642350731 01 2021...

Страница 12: ...flush control 4 Open the urinal flush control cover 5 Disconnect the solenoid valve cable 6 Remove the solenoid valve unit 7 Demount the securing clamp 8 Demount the coupling 12 54043198642350731 01 2...

Страница 13: ...e the new solenoid valve 11 Mount the new solenoid valve 12 Mount the coupling 13 Mount the securing clamp 14 Snap the solenoid valve unit into place 15 Connect the cable for the solenoid valve 540431...

Страница 14: ...16 Close the urinal flush control cover 17 Install the urinal flush control 18 Close the protection flap Result The urinal is ready for operation 14 54043198642350731 01 2021 967 135 00 0 05...

Страница 15: ...cing valve This can cause the pressure setting to be adjusted Replace the water pressure reducing valve in the event of clogging 1 Remove the fastening for the urinal ceramic PP 2 Remove the urinal ce...

Страница 16: ...4 Demount and dispose of the water pressure reducing valve 5 Mount the new water pressure reducing valve 6 Open the angle stop valve 7 Mount the ceramic 16 54043198642350731 01 2021 967 135 00 0 05...

Страница 17: ...8 Fasten the ceramic in place PP 1P 54043198642350731 01 2021 967 135 00 0 05 17...

Страница 18: ...range 1 short signal tone sounds every second No flush is actuated The function switches off automatically after 10 minutes Checking the user recog nition On OK Off OK 23 BlocFlush Blockiere Block flu...

Страница 19: ...se once the delay DelFollwF FolgVerz has elapsed menu item 42 Flushing out the urinal ceramic Filling the urinal trap On ON Off OFF Off OFF 35 PostFlush NachSp l Activate postflush Flushes for 2 s 3 s...

Страница 20: ...valT IntervalZ Set the flush interval for the interval flush Is active when menu item 30 Activate interval flush is ON EIN 1 168 h 24 h 24 45 CleanTime ReiniZeit Set cleaning time Defines the duration...

Страница 21: ...61 Uses SumBenut Total number of uses Displays the number of uses since commissioning uses 62 Flushes SumSp l Total number of flushes Displays the number of flushes since commissioning flushes 63 Day...

Страница 22: ...d e g 1015 calendar week 10 2015 WWYY 74 TypePower Netz Batt Type of power supply Indicates whether it is a mains operated AC or a battery operated DC or generator operated DC urinal flush control DC...

Страница 23: ...tT has elapsed menu item 49 No flush is released if the interval is still active The interval starts once activated once the previous interval has elapsed regardless of the number of uses W E QW7 E QW...

Страница 24: ...electrical equipment are obliged to take back old equipment and to dispose of it appropriately The symbol indicates that the product cannot be disposed of with non recyclable waste Old equipment shou...

Отзывы: