![Geberit Chicago Faucets Commander Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/geberit/chicago-faucets-commander/chicago-faucets-commander_manual_4072301021.webp)
Chicago Faucets
®
Commander
™
Handheld Programming Unit User Guide
Page 21
CF2026 / 07/19
SECTION 2: Scanning, Mode and Setting Adjustments
2.6.1.5 Running Mode
Water Saver
—
Fitting operates when user is detected and stops after a brief delay when user detection ends. However, it is saves more water than Normal
Mode in that the maximum run time is typically shorter AND there is a mandatory time delay between activations to discourage multiple quick on cycles
(and waste water). Default setting for SSPS fittings.
Water Saver Running Time
—
Choose “Factory” pre-set for 10
second running time.
Choose “Custom Setting” and
adjust running time from 3 to 180
seconds with slide bar.
Set
—
Tap “SET” to save and
execute settings.
Min Interval Between Uses
—
Choose “Factory” pre-set for 2
second delay time before new
detections are registered.
Choose “Custom Setting” and
adjust delay time from 1 to 5
seconds with slide bar.