EN
Cancelling the pressing
procedure
▶
Press and hold release button.
Result
✓ The roller drive in the pressing tool
returns to its starting position. The
pressing procedure must be repeated for
a complete press connection. The
pressing attachment must not be
removed or rotated at this time.
Rectifying malfunctions
Fault
Cause
Action
Unable to activate the
pressing tool out of idle
state, no LEDs are lit.
Mains cable is not
connected.
▶ Connect the mains plug to the power
supply system.
Mains cable or mains
plug is defective.
▶ Have the mains cable and mains plug
examined at an authorised repair
shop and replaced if necessary.
Green LED flashes.
Retaining pin has
been inserted incor-
rectly or has not been
pushed in until the
stop position is
reached.
▶ Check the retaining pin for damage.
▶ Push the retaining pin in until the stop
position is reached.
Green LED flashes and
roller drive moves back to
its starting position.
Retaining pin has
come loose.
▶ Check the retaining pin for damage.
▶ Push the retaining pin in until the stop
position is reached: green LED lights
up.
▶ Check the pressfitting for tightness
and repeat the pressing operation if
necessary.
Red LED flashes.
Start button was
released too soon.
▶ Press and hold release button: roller
drive moves to its starting position.
▶ Repeat the pressing operation: press
the start button for at least 2 seconds.
Release button was
pressed or pressing
tool was not in
starting position.
▶ Release start button.
▶ Press and hold release button: roller
drive moves to its starting position.
▶ Repeat the pressing operation: press
the start button for at least 2 seconds.
Pressing tool is
outside of the
operating
temperature.
▶ Bring the pressing tool into a warmer
environment or leave it to cool down.
▶ Bring the pressing tool to the required
operating temperature by performing
multiple blank pressing operations
(pressing operations without a fitting).
18014400403961739-1 © 07-2020
968.385.00.0(01)
29