Menu item
Description
Application
Value
Factory
setting
Functions
[Interval flush]
Activate the interval flush
• User-controlled: A flush is
actuated at the end of the [flush
interval], whereby the flush
interval is restarted with every
use. The flush time is
determined by the [flush time]
value.
• Interval-controlled: A flush is
actuated at the end of the [flush
interval], regardless of the
number of uses. The flush time
is determined by the [flush time]
value.
• Difference flush: A flush is
actuated at the end of the [flush
interval], regardless of the
number of uses. If flushes have
already been performed within
the [flush interval], the postflush
only makes up the difference in
[flush time].
• To fill the trap in the
case of low user
frequencies
• To flush out standing
water in the pipe
(hygiene function – to
prevent stagnation)
[Off], [User-
controlled],
[Interval-
controlled],
[Difference
flush]
[User-
controlled]
[Flush time]
–
1–200 s
5 s
[Flush interval]
–
1–168 h
24 h
[Flush volume]
The flush volume for the interval
flush is calculated from the [flush
time] above and the [flush volume
settings].
• Flush volume display
–
–
[Power-on flush]
A flush is actuated after switching
on the mains voltage.
• To perform central flush
actuation
• To confirm a function
On/Off
Off
[Flush volume
setting]
[Full flush]
This flush volume sets the time for
opening the flush valve for a full
flush. The specified flush volumes
are reference values and depend
on the WC ceramic appliance.
• Optimum flushing of the
WC ceramic appliance
• For the statistics
function
• To calculate the flush
volume of the interval
flush
4.5 l
5 l
5.5 l
6 l
6.5 l
6 l
[Partial flush (statistics)]
The flush volume of the partial
flush must be specified to
calculate the water consumption.
The flush volume of the partial
flush can be set on the flush valve.
• For the statistics
function
• To calculate the flush
volume of the interval
flush
1–5 l
2.5 l
[Flow pressure (statistics)]
The flow pressure in the supply
pipe must be specified to calculate
the water consumption.
• For the statistics
function
• To calculate the flush
volume of the interval
flush
0.5–10 bar
3 bar
2 / 3