Cody Light HF Door-opener (up to 4 pass code for the relay output)
The four possible pass codes are programmed in the easiest way.
There are four DIP switches on the logic unit (see picture below). These four DIP switches correspond
to the four memory slots for each pass code.
Put DIP of the
desired memoy
slot to ON
Keypad
sound signal
1x long
Enter 4 or 5
digit pass code
push
button
Entering a pass code
A correct code is detected; the corresponding relay is switched!
Before the actual pass code, you can press any other keys to prevent fraud.
If an incorrect pass code is entered, you will hear a sound signal (3 beeps).
Entering a new pass code is only possible after the lock-out period (factory: 20 sec.) which end is
signalled by a long sound signal.
Creating a new pass code
Keypad
Enter 4 or 5
digit pass code
sound signal
1x long
push
button
Set all DIP to
OFF
The new pass code is now saved!
Put DIP of the
desired memoy
slot to ON
sound signal
1x long
push
button
push
button
Set all DIP to
OFF
The selected memory slot of the pass code
is now deleted!
Deleting a pass code