Hint!
Welding method: We recommend using the automatic orbital welding
method. All welding work should only be performed by certified
welders or machine operators (orbital welders).
Housing O-rings: When assembling the valve always replace the
housing O-rings to ensure that the valve is tight.
6.6
Pneumatic connections
6.6.1
Air Requirement
Actuator type
Actuator diameter [mm]
Air requirement (dm
3
n
/
Stroke)
dm
3
n at 1.01325 bar, at
0°C according to DIN
1343
A...
99
0.16
B...
109
0.26
B...5
109
0.34
C...
135
0.42
C...5
135
0.54
D...
170
0.70
E...
210
1.10
E...5
210
1.40
E...6
210
2.00
S...6
261
3.20
D...6
170
1.30
R...¹
170
1.60
S...¹
210
2.00
T...¹
210
3.10
T...6¹
210
4.00
U...6¹
261
5.10
1
Actuators with booster cylinder for increasing the pneumatic actuating force
when lower control air pressures are used
6.6.2
Establishing Hose Connections
To ensure reliable operation, the compressed air hoses must be cut exactly
square.
Tools required:
•
A hose cutter
Assembly and installation
Pneumatic connections
430BAL008451EN_2
24.10.2017
33