Technical data: Compressed air supply
Designation
Description
Air hose
- metric
Material PE-LD outside Ø 6 mm
Inside Ø 4 mm
- Inch
Material PA outside-Ø 6.35 mm
Inside Ø 4.3 mm
Air consumption
(depending on the operating
pressure)
2 to 3.8 l for DN 25 to DN 125
3.5 to 6.5 l for DN 150
Product pressure
5 bar (72.5 psi) configuration with standard actuator
max. 10 bar (116 psi) configuration with correspondingly designed
actuator
>10 bar (145.0 psi) for static applications and on request
Resistance to pressure surges*
DN 80-100/OD 4"
max. 25 bar (362.6 psi)
Control air pressure
6 bar, max. 8 bar
Control air
acc. to ISO 8573-1
- Solid particle content:
Quality class 6
Particle size max. 5 µm
Particle density max. 5 mg/m
3
- Water content:
Quality class 4 max. dew point +3 °C
If the unit is used at higher altitudes or at low ambient temperatures, the
dew point must be adapted accordingly.
- Oil content:
Quality class 3, ideally oil-free, max. 1 mg oil for 1 m
3
air
*Resistance to pressure surges when the valve is in the closed state
5.3
Cleaning connection
Connection for the hose
1 ", DN 25
Ø 4/6 mm
DN 40...100
Ø 8/6 mm
1.5"...4" OD; 2''...4'' IPS
Ø 8/6 mm
DN 125, 150; 6" IPS; 6'' OD
Ø 10/8 mm
Service pressure for the optimal cleaning
•
min. 2 bar (29 psi)
•
max. 5 bar (72.5 psi)
The duration of the rinsing operation via the rinsing valve depends on the type of
soiling and typically ranges between 10 and 60 seconds.
The durability of the components of the cleaning connection (sealing disc,
support sleeve, PTFE hose) is dependent on the style, pressure and temperature
of the required medium.
Technical data
Cleaning connection
430BAL008386EN_3
07.02.2022
25
Содержание VARIVENT DN 25
Страница 79: ...Appendix 430BAL008386EN_3 07 02 2022 79...