10.7.5 Checking assembly
Fig.26
When the valve is closed, the lower edge of the cleaning hood (1) should be flush
with the underside of the abutment (2).
10.7.6 Reconnect the cleaning hose
Prerequisite:
•
The cleaning hose is made of plastics. When screwing the cleaning hose on,
it can become easily constricted in the area of the sealing disc and the
cleaning hose can become detached. Therefore, during assembly of the
cleaning hose, insert sleeves must be used.
Cleaning hose preparation
Carry out the following steps:
1.
Cut off the cleaning with the hose cutter at a right angle.
2.
Place insertion sleeves up to the edge of the hose.
3.
Grease the threads and cone of the fitting, as well as the sealing disc and the
threads of the union nut.
Hint!
GEA Tuchenhagen recommends Rivolta F.L.G. MD-2 and PARALIQ
GTE 703. These lubricants are approved for foodstuff and are resistant
to beer froth. They have the NSF-H1 (USDA H1) registration. PARALIQ
GTE 703 can be ordered under mat. no. 413-064, and Rivolta F.L.G.
MD-2 can be ordered under mat. no. 413-071 from GEA Tuchenhagen.
Fitting the cleaning hose
1.
Slide the union nut (2) and sealing disc (1) over the cleaning hose disc.
Maintenance
Installation
430BAL008360EN_5
07.02.2022