2
Safety
2.1
Intended use
The T.VIS M-15 control top can be used for the pneumatic and electrical
connection of all Tuchenhagen process valves with VARIVENT adaptation. Using
the device for any other purpose is considered contrary to its designated use.
The control top T.VIS M-15 is available as
•
position indicator without solenoid valve
•
with solenoid valve as control top
The control top T.VIS M-15 is completely installed on the dedicated actuator/
adapter of the process valve by means of a clamp connection. Due to the internal
air guiding system, the control air can pass directly from the control top into the
actuator on suitable process valves. For process valves which do not allow the air
to be guided internally, the control top has a connection option for supplying the
air externally via a hose.
With T.VIS M-15 the following can be carried out for all valves:
•
monitoring the non-actuated position of the valve disk,
•
monitoring the actuated position of the valve disk,
•
provision of an PNP or NPN output for feedback signals,
•
coloured visualization of the valve position and status via the illuminated
dome fitted on the control top.
In addition, with T.VIS M-15 you can monitor the non-actuated position of the
double-disk with an initiator in the lantern for all double-seat valves.
The control top T.VIS M-15 may not be used in areas where ATEX approval is
required.
Hint!
The manufacturer will not accept any liability for damage resulting
from any use of the valve which is not in accordance with the
designated use of the valve. The risk is borne solely by the operating
company.
2.1.1
Requirements for operation
The prerequisite for reliable and safe operation of the component is proper
transportation and storage as well as professional installation and assembly.
Operating the unit within the limits of its designated use also involves adhering to
the operating, inspection and maintenance instructions.
2.1.2
Improper operating conditions
The operational safety of the component can not be guaranteed under improper
operating conditions. Therefore avoid improper operating conditions.
The operation of the component is not permitted if:
•
Persons or objects are in the danger zone.
Safety
Intended use
430BAL010697EN_2
15.04.2020
9
Содержание T.VIS M-15
Страница 6: ...430BAL010697EN_2 6 15 04 2020...
Страница 53: ...Fig 27 Assembly and installation Electrical connections 430BAL010697EN_2 15 04 2020 53...
Страница 55: ...Fig 28 Assembly and installation Electrical connections 430BAL010697EN_2 15 04 2020 55...
Страница 111: ...14 Spare parts list Switch bar T VIS M 15 Fig 82 Spare parts list Switch bar T VIS M 15 430BAL010697EN_2 15 04 2020 111...
Страница 119: ...Appendix 430BAL010697EN_2 15 04 2020 119...
Страница 120: ......