6.6.8
Mounting to a T-smart Single-Seat and Double-Seal Valve
Fig.39
Requirement:
•
Pay attention not to kink the air hoses when mounting the control top.
Notice
The permanent magnet on the switch bar is fragile.
Damage to the permanent magnet.
► Protect the permanent magnet against impact stress.
Notice
Magnetic fields resulting from the permanent magnet on the
switch bar.
Magnetic fields can delete data carriers and affect or destroy electronic or
mechanical components.
► Protect the components against the magnetic fields from the switch bar.
Carry out the following steps:
1.
Screw the switch bar (1) into the piston rod A4.1 and tighten with open-end
wrench SW13 at (1.1), torque 2 Nm.
2.
Fit the control top (B) over the switch bar (1) and on the actuator (A.4).
3.
Tighten the clamp connection (15) and screws (39) to a torque of 1 Nm.
4.
Align the pneumatic and electrical connections in accordance with the valve
block configuration.
!
As internal air guiding is not possible on these valve types, connect the air
connection (Y1) on the control top to connection (A.4.2) on the actuator with
an air hose (L).
5.
Perform commissioning, see Chapter 6, Page 36 and Chapter 7, Page 73.
®
Done.
Assembly and installation
Mounting the Control Top to Different Valves
430BAL010697EN_2
70
15.04.2020
Содержание T.VIS M-15
Страница 6: ...430BAL010697EN_2 6 15 04 2020...
Страница 53: ...Fig 27 Assembly and installation Electrical connections 430BAL010697EN_2 15 04 2020 53...
Страница 55: ...Fig 28 Assembly and installation Electrical connections 430BAL010697EN_2 15 04 2020 55...
Страница 111: ...14 Spare parts list Switch bar T VIS M 15 Fig 82 Spare parts list Switch bar T VIS M 15 430BAL010697EN_2 15 04 2020 111...
Страница 119: ...Appendix 430BAL010697EN_2 15 04 2020 119...
Страница 120: ......