background image

4

   

8164-9001-400 / 1198

1.4 General layout plan

Fig. 3

9

1

8

14

11

13

10

12

7

3

2

A

C

6

5

4

B

D

A

Water

B

Compressed air

C

Dirty oil feed

D

Clean oil discharge

1

Control unit C7-623 and motor control for centrifuge

Motor control feed pump 

Motor control sludge pump 

2

Water pressure reducer 

3

Feed assembly with solenoid valve for
filling, displacement and operating water

4

Compressed air control unit 

5

Pneumatic 3/2-way valve with
manual adjustment and solenoid valve for control air
(fitted in the dirty oil line of the separator)

6

PT 100 oil feed min./max. temperature monitoring 

7

Pressure switch (for monitoring the clean oil discharge)

8

Connections for electrical power supply 

9

Klaxon 

10 Water discharge valve

11

Circuit valve

12 Pressure switch - sludge space monitoring

13 Water sensor

14 Terminal box (fitted to separator)

On special order only.

Содержание SIMATIC C7-623

Страница 1: ...WMS 01 Program 0 Program 1 L Test SMS 36 SMS 96 7 8 9 4 5 6 1 2 3 0 ESC INS DEL DIR HARD COPY SHIFT HELP ENTER SF BAF FRCE DC5V STOP RUN D E F A B C SIMATIC C7 623 ACK DOWN ALARMS SERIES 1 2 CHECK Sep...

Страница 2: ......

Страница 3: ...III 8164 9001 400 1198 Subject to modification...

Страница 4: ...s can therefore result in serious injury or damage For this reason only suitably qualified specialists are allowed to work on the units Protective measures should be taken in line with national and lo...

Страница 5: ...s the unit is improperly maintained or serviced by persons other than Westfalia Separator service personnel or if the machine is not applied in accor dance with the intended use Westfalia Separator AG...

Страница 6: ...ation it is therefore imperative that the manual is indeed handed over to these per sons In the event of any queries please state the model designation and the se rial number see nameplate inside the...

Страница 7: ...em function menu 26 3 4 2 Calling up the system function menu 27 3 4 3 Exiting the system function menu 28 3 5 Password protection 29 3 5 1 Entering the password 29 3 6 The start screen 30 3 7 Interfa...

Страница 8: ...d error indicators 92 6 2 Alarm descriptions 93 6 2 1 Separator motor protection input 0 1 93 6 2 2 PSL Clean oil discharge input 0 2 95 6 2 3 PSH Clean oil discharge input 0 3 special design 97 6 2 4...

Страница 9: ...1 General description 1 8164 9001 400 1198 1 1 Application 2 1 2 Equipment 2 1 3 Control cabinet 3 1 4 General layout plan 4...

Страница 10: ...ters of this manual The illuminated four line LC display provides information about the operating and malfunction condition of the separator and depending on the programming dis plays relevant process...

Страница 11: ...3 8164 9001 400 1198 Fig 2 The C7 623 control unit is built into the door of the control cabinet ready for connec tion An order specific drawing is in the appendix to this manual 1 3 Control cabinet...

Страница 12: ...for filling displacement and operating water 4 Compressed air control unit 5 Pneumatic 3 2 way valve with manual adjustment and solenoid valve for control air fitted in the dirty oil line of the sepa...

Страница 13: ...2 1 Design 9 2 2 Classification specifications 9 2 3 Special designs 10 2 4 Assembly 10 2 4 1 Control unit 10 2 4 2 Electrical connection 11 2 4 3 Fuse terminals 11 2 5 Installing the control unit in...