Instructions for use and maintenance
This manual is owned by GEA Niro Soavi Any reproduction, even partial, is prohibited.
06C100-9C0
GEA Niro Soavi
99
6.4 Stopping the machine
In order to ensure safety for the operator, the electrical system is designed to handle NORMAL and
EMERGENCY STOPS.
6.4.1 Normal stop
The machine is stopped as follows:
• cut off the homogenizing pressure with the pneumatic switch, turning it OFF;
• press the stop button (if present on the machine's control panel) or produce a stop signal with
the control and command system. For machines with electrical enclosure supplied by
GEA Niro
Soavi S.p.A.
this stops the auxiliary motors (if present) and main motor in the right sequence,
which is given in the TECHNICAL DATASHEETS enclosed with Chapter 11 of this manual for the
client's use in building his own electrical cabinet if not supplied by
GEA Niro Soavi S.p.A.
;
• shut off power with the master power switch.
6.4.2 Emergency stop
In cases of danger or serious malfunction, you can stop the machine immediately by pressing the
emergency stop button on the front panel (see figure below).
Then shut off the pressure as described above.
CAUTION:
Before restoring the machine's operability, eliminate the cause of the emergency stop.
CAUTION:
Resetting the emergency stop button does not start the machine, but enables it for starting
in the normal manner.
EMERGENCY STOP
FIG. 6.6
Содержание Niro Soavi One7TS