28
D
GB
F
E
96416-03.2017-DGbFEIRu
7.3 Spare part recommendation
HG44e / ...
475-4 (S)
565-4 (S)
665-4 (S)
770-4 (S)
Designation
Item No.
Item No.
Item No.
Item No.
Set of gaskets kit
81598
Valve plate kit
80965
80966
Oil pump kit
80950
Oil sump heater kit
230 V ~
81252
Only use genuine GEA spare parts!
HG56e / ...
850-4 (S)
995-4 (S)
1155-4 (S)
Designation
Item No.
Item No.
Item No.
Set of gaskets kit
81599
Valve plate kit
80965
80966
Oil pump kit
80950
Oil sump heater kit
230 V ~
81252
7.1 Preparation
7
|
Maintenance
7.2 Work to be carried out
In order to guarantee optimum operational reliability and service life of the compressor,
we
recommend
carrying out servicing and inspection work at regular intervals:
Oil change:
-
not mandatory for factory-produced series systems.
-
for field installations or when operating near the application limit: for the first time after 100
to 200 operating hours, then approx. every 3 years or 10,000 - 12,000 operating hours.
Dispose of used oil according to the regulations; observe national regulations.
Annual checks:
Oil level, leak tightness, running noises, pressures, temperatures, function of
auxiliary devices such as oil sump heater, pressure switch.
WARNING
Before starting any work on the compressor:
Switch off the compressor and secure it to prevent a restart.
Relieve compressor of system pressure.
Prevent air from infiltrating the system!
After maintenance has been performed:
Connect safety switch.
Evacuate compressor.
Release switch lock.