Handling and assembly
Hydraulic door on fill opening assembly (optional)
2018-9015-001
09-2016
5.17
Ladder assembly (optional)
● Install the ladder on the spreader
using four bolts and locknuts.
5.18
Hydraulic door on fill opening assembly (optional)
Warning!
Beware of potential falls: always walk on the nonslip band installed on
the product.
Attention!
To lift the hydraulic door on fill opening, use a lifting device with a
minimum lifting capacity of 375 lbs [165 kg].
1
● Lift the hydraulic door by the lifting rings (1) using safety chains. Make sure
the door is open before lifting it to ease installation;
● There are two hydraulic hoses installed on top of the tank. Connect one of
the hydraulic hoses to the ball valve located on the door frame. Connect the
second hose to the cylinder;
● Bolt the door using provided hardware;
● Open the ball valve located on the door frame.