ZDP364NRPSS (Natural Gas)

ZDP364LRPSS (Liquid Propane)

GE Monogram

® 

36" Dual-Fuel Professional Range with 4 Burners and Grill

Dimensions and Installation Information (in inches) 

Electrical Requirements

Ranges must be supplied with 208/240V, 60Hz, and 
connected to an individual, properly grounded branch circuit 
protected by a circuit breaker or time-delay fuse. Install a 30-
amp circuit for 36" ranges. The receptacle must be a NEMA 
14-50R device to accept the four-prong plug on the range.

Optional Backsplash Accessories

The range requires a 12" minimum clearance to a vertical 
combustible surface at the rear. A backsplash is required 
for installations with less than 12" clearance. The following 
backsplash accessories are available, or a custom, non-
combustible backsplash can be used.
Order one with a 36"-wide range backsplash 

ZX12B36PSS–12" backsplash

ZXADJB36PSS– 30"-36" adjustable-height backsplash with 

warming shelf

Side View with Required Backsplashes

Locate gas and  
electric as shown

Gas Supply

•  The natural gas models are designed to 

operate at 5" water column pressure. 
For proper operation, the pressure of 
the natural gas supplied to the regulator 
must be between 7" and 13" water 
column.

•  The LP models are designed to operate 

at 10" water column pressure. For 
proper operation, the pressure of the LP 
gas supplied to the regulator must be 
between 11" and 13" water column.