Optional Backsplash Accessories

The range requires a 12" minimum clearance to a vertical combustible 

surface at the rear. A backsplash is required for installations with  

less than 12" clearance. The following backsplash accessories are 

available, or a custom, non-combustible backsplash can be used.

Backsplashes: Order one with a 36"-wide range 

zX12B36hss

–12" backsplash

zX22B36hss

– 22" backsplash with warming shelf

Backsplash with Warming shelf

All Monogram Professional Wall-Mounted Hoods feature infrared 

warming lights. The 22"-high warming shelf is a perfect complement 

when installed with the tapered or straight-sided hoods.
 If you choose to install this range with a Restaurant-Style  

Professional Hood (ZV36RSFSS), no additional accessories are  

required. These hoods are shipped with a stainless steel  

backsplash and warming shelf.

side View with a Backsplash

Electrical Requirements

Ranges must be supplied with 208/240V, 60Hz, and connected to 

an individual, properly grounded branch circuit protected by a circuit 

breaker or time-delay fuse. Install a 30-amp circuit for 36" ranges. The 

receptacle must be a NEMA 14-50R device to accept the four-prong 

plug on the range.

zdp36n4dhss 

(natural Gas)

 

zdp36l4dhss 

(liquid propane)

 –  GE Monogram 36" dual Fuel professional Range with 

4 Burners and Griddle

For answers to your Monogram,

®

 GE Profile

 or  

GE

®

 appliance questions, visit our website at  

GEAppliances.com or call GE Answer Center

®

  

service, 800.626.2000.

Listed by  

Underwriters  

Laboratories

Backguard

36" Min. 

to 

Combustibles

0" Clearance

12" Min. to Combustibles or 

0" Min. to Combustibles

with 12" or 22" Backsplash

Gas supply

•  Natural gas models are designed to operate at 5" water column 

pressure. A regulator is required at the natural gas source to  

provide maximum of 7" water pressure to the range regulator.

•  The liquid propane models are designed to operate at 10" water 

column pressure. A regulator is required at the LP source to provide 

maximum of 14" water pressure to the range regulator.

4"

4"

4"

12"

12"

Gas 

Supply

36"

1-1/2"

4"

Electric

Supply

Locate gas and  

electric as shown

specification Revised 3/08 

130542