GE WSM2700WWW - 27

Installation Instructions

DOOR VENTILATION OPENING

A minimum of 120 square inches of opening, equally
divided at top and bottom, is required. Air openings are
required to be unobstructed when a door is installed. 
A louvered door with equivalent air openings for the 
full length of the door is acceptable.

When louvers or registers are placed in door openings,
the free air openings of the louvers or registers must
equal 120 square inches.

MISCELLANEOUS REQUIREMENTS

LOCATION

• The appliance must be installed on firm flooring to

minimize vibration during spin cycles. Concrete flooring
is best, but wood base is sufficient, provided the floor
support meets FHA standards.

• The appliance should not be installed on rugs or

exposed to the weather.

INSIDE EXHAUSTING

• If the installation makes it possible to exhaust to the

outside, there must be a clearance of 4

between the

top of the appliance and the soffit.

60 Sq. In.

60 Sq. In.

ALCOVE OR CLOSET INSTALLATION

• If your dryer is approved for installation in an alcove 

or closet, it will be stated on a label on the back of 
the dryer.

• TO PREVENT LARGE AMOUNTS OF LINT AND MOISTURE

FROM ACCUMULATING AND TO MAINTAIN DRYING
EFFICIENCY, THIS MACHINE MUST BE EXHAUSTED
OUTDOORS.

• DO NOT install this appliance with less than 

the minimum clearances shown above.

CONSIDERATION MUST BE GIVEN TO PROVIDE ADEQUATE
CLEARANCES FOR INSTALLATION AND SERVICE.

CAUTION:

DO NOT INSTALL THIS APPLIANCE

IN A CLOSET WITH A SOLID DOOR.

1

1

0

0

0

60 Sq. In.

60 Sq. In.

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

MOBILE HOME INSTALLATION

• Installation must conform to Manufactured Home

Construction and Safety Standard, Title 24 CFR, 
Part 32-80.

• The dryer must be exhausted to the outside with 

the termination securely fastened to the mobile 
home structure.

• The exhaust MUST NOT be terminated beneath 

the mobile home.

• The exhaust duct material MUST NOT support

combustion.

• For Electrical Connections see 

CONNECTING APPLIANCE

USING 4-WIRE CONNECTION.

CONSIDERATION MUST BE GIVEN TO PROVIDE ADEQUATE
CLEARANCES FOR INSTALLATION AND SERVICE.

Содержание WSM2700WWW - 27" Unitized Spacemaker Washer

Страница 1: ...exposed to water and or weather Save these instructions Installers Be sure to leave these instructions with the customer This appliance must be properly grounded and installed as described in these in...

Страница 2: ...siphoning 7 6 5 4 3 2 1 2 Plastic spacer block Installation Instructions Tub blocking pad Shipping blocks Shipping clips Rear vent only Drain hose Shipping carton corner posts Foam shipping pad Mecha...

Страница 3: ...and remove the panel Route the inlet hoses drain hose and power cord through the rear access area for temporary holding when moving the appliance to the operating location To ensure the Spacemaker is...

Страница 4: ...will fall below freezing If appliance is stored or transported in freezing temperatures be sure all water from the fill and drain systems has been removed 19 18 17A 17E 17D 17C 17B 17 DRAIN REQUIREME...

Страница 5: ...outlet Return to Step 15 on page 3 NOTE THIS APPLIANCE IS NOT APPROVED FOR 120 VOLT OPERATION 9 8 7 2 6 5 4 3 1 Center silver colored screw 3 WIRE CONNECTION UNGROUNDED NEUTRAL This appliance is manuf...

Страница 6: ...nd cleaning of the exhaust system especially at turns and joints Exhaust system shall be inspected and cleaned at least once a year Remove and discard existing plastic or metal foil duct and replace w...

Страница 7: ...VENT CONT UL Listed Flexible Metal Foil Type Transition Duct In special installations it may be necessary to connect the dryer to the house vent using a flexible metal foil type duct A UL listed flexi...

Страница 8: ...OVE OR CLOSET INSTALLATION If your dryer is approved for installation in an alcove or closet it will be stated on a label on the back of the dryer TO PREVENT LARGE AMOUNTS OF LINT AND MOISTURE FROM AC...

Отзывы: