FIELD SERVICE MODE ENTRY

From an idle state only (all LEDs off), press 
and hold 

Start 

button while rotating the cycle 

selection knob 180 degrees (7 clicks) and 
then release the 

Start 

button.

• Once service mode is entered all LEDs will 
be flashing.
– On 7-segment display models: (0) will be 
displayed for Test (0).
– On models without a 7-segment display: All 
of the status LEDs above the cycle knob will 
be lit.

• The cycle selection Knob is now used to 
control the test selection menu.

– Rotating the knob clockwise will 

increment the test numbers in the
display.

– Rotating the knob counter clockwise will 

decrement the test number in the display.

– Models without 7-segment display: Will 

display tests using the status lights above the 
cycle knob in a binary format. (See Binary 
Chart)

– Turning the knob to go to a different test will 

terminate any current active state.

• Once the test number is selected, pressing 

Start 

will begin the selected test.

Exit Field Service Mode

• Field service mode will time out after 30 minutes 
if there is no user activity.

• Models without 7-segment display: Press and 
hold the 

Start 

button for 3 seconds

• Models with a 7-segment display: Press 

Power 

button

SERVICE MODE TEST 17-
Change Personality  

Pressing 

Start 

will start the test. Press 

Start 

button again and the next valid personality should 
be displayed. Press and hold the 

Start 

button to 

select the correct personality. The control will go to 
an idle state. All LED’s off.

Note: 

Upon entering test 17 for models,

GTW220**K0, K1 and K2, 
HTW240**K0 and K1, and also HTW200**K3 
and higher 
the cycle status LED’s 

will not be lit for 

personality “0”.

Note: 

If the personality ID is already set and you 

try to set the same personality the control will 
NOT go to an idle state. Ensure the correct 
personality ID is being entered. 