background image

WH00X28180

Part Install Instructions

Overview 

– Procedure for programming new control boards 

when all LED’s are flashing.

Applicable To The Following Main Boards: 
WH18X28174, WH18X28175, WH18X28176, WH18X28177 
and WH18X28178

!

IMPORTANT SAFETY NOTICE

The information in this part instruction is intended for use by 
individuals possessing adequate backgrounds of electrical, 
electronic and mechanical experience. Any attempt to repair a 
major appliance may result in personal injury and property damage. 
The manufacturer or seller cannot be responsible for the 
interpretation of this information, nor can it assume any liability in 
connection with its use.

!

WARNING

To avoid personal injury, disconnect power before servicing this 
appliance. If electrical power is required for diagnosis or test 
purposes, disconnect the power immediately after performing the 
necessary checks. RECONNECT ALL GROUNDING DEVICES If 
grounding wires, screws, straps, clips, nuts, or washers used to 
complete a path to ground are removed for service, they must be 
returned to their original position and properly fastened.

Parts Included: 

Control Board

Instruction Sheet

1. Press Start button. 

LED’s will stop flashing and the personality ID can be selected. 

Models with seven segment display will show the personality ID number in the display.

Models without seven segment display will show the personality ID number on the 
status LED’s using binary coding. (See binary chart on reverse side)

2. Press and release the Start button

to increment to the next personality ID number.  

The first personality may be “0” and all cycle status LED’s will be off. 

When the end of the ID list is reached the control will wrap around to the beginning of 
the personality ID number list.

3. Press and hold the Start button for three seconds 

when the correct personality ID number 

is in the display or if the correct status LED’s are lit for the personality ID number needed.

This will save the personality ID number and the control will go to an idle state.

NOTE: 

If an error is made programming the control or the LED’s are not flashing, enter Field 

Service Mode as shown on the last page of these instructions. Use service mode test 17 to enter 
the correct personality.