background image

a

WF180

e

Through the Wall Exhaust Fan

User’s Guide

210575001 Rev. A 1-08

Item Stock Number(s): WF180

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.

PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH

INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions should always be followed to reduce

the risk of fire, electric shock and injury to person, including the following:

1. Read all instructions before installing or using

exhaust fan.

2. Use this unit only in the manner intended by the

manufacturer. If you have questions, contact the
manufacturer.

3. Before servicing or cleaning the unit, switch power

off at service panel and lock the service disconnecting
means to prevent power from being switched on

SAVE THESE INSTRUCTIONS

IMPORTANT INSTRUCTIONS -

OPERATING MANUAL

accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.

4. Installation work and electrical wiring must be done

by qualified person(s) in accordance with all applicable
codes and standards, including fire-related construction.

5. Sufficient air is needed for proper combustion and

exhausting of gases through the flue (chimney) of

1 of 8

www.geelectrical.com

Содержание WF180

Страница 1: ... Read all instructions before installing or using exhaust fan 2 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer 3 Before servicing or cleaning the unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on SAVE THESE INSTRUCTIONS IMPORTANT INSTRUCTIONS OPERATING MANUAL accident...

Страница 2: ... have 1 Grill 1 Grill Knob 1 Wiring Compartment and screws 1 Motor 1 Housing 1 Instruction Safety Sheet NOTE This fan is designed to mount between exterior walls 4 1 2 to 9 1 2 in thickness 2 Remove the motor bracket assembly from the fan housing by loosening the two screws which secure the bracket in place Figure 1 3 Slide the inner housing out from the outer housing and set aside in a safe place...

Страница 3: ...oles on the four corners of the housing Seal the flange where the housing meets the wall with caulk Figure 7 SECTION 3 Wiring CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION CAUTION ALLELECTRICALCONNECTIONSMUST BE MADE IN ACCORDANCE WITH LOCAL CODES ORDINANCES OR NATIONAL ELECTRICAL CODE IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING SECURE...

Страница 4: ...crews Rotate the blower wheel by hand to ensure it spins freely Now plug the fan motor into the receptacle Figure 1 2 Install grill by positioning over the inner housing and aligning the center hole on the grill with the hole on the motor bracket Screw one side of the included grill bolt into the hole on the motor bracket and the other side into the grill knob and turn to tighten until the grill i...

Страница 5: ...o receptacle in housing Restore power to unit 1c Wiring is not connected properly 1c Turn off power to unit Check that all wires are connected 1d Motor has stopped operating 1d Replace motor 2 Fan is operating but air moves slower than normal 2 Obstruction in the outer housing 2 Check for any obstructions where the fan exhausts to the outside 3 Fan is operating louder than normal 3a Motor is loose...

Страница 6: ...llation problem contact your dealer or installer You are responsible for providing adequate electrical exhausting and other connecting facilities See the Installation Instructions provided with this product for electrical exhaust and connection details Replacement of house fuses or resetting of circuit breakers Failure of the product if it is used for something other than the intended purpose of m...

Страница 7: ...et 5S2203005 6 1 Spring 5S2203006 7 1 Damper 5S2203007 8 1 Gasket 5S2203008 9 1 Gasket 5S2203009 10 1 Wire Compartment 5S2203010 11 1 Ground Screw 5S2203011 Qty Description Replacement Part 12 1 Wire Compartment Cover 5S2203012 13 1 Polarized Receptacle 5S1999001 14 1 Blade 5S2203013 15 1 Motor 5S2203014 16 1 Motor Bracket 5S2203015 17 4 Mounting Screws 5S2203016 18 1 Blade Spring 5S2203017 19 1 B...

Страница 8: ...210575001 Rev A 1 08 8 of 8 www geelectrical com ...

Отзывы: