background image

 

Installation 

 

GFK-2299 VersaMax 

Expansion I/O Interface Card 

6

Connecting the Expansion Cable 

Connect the cable from the expansion port on the Expansion 
Transmitter to the Expansion Receivers as shown below. 

QuickPanel

Control with

Expansion

Interface Card

IC200CBL601,

602,615

Expansion Rack1

Expansion Rack7

PS

ERM

PS

ERM

Terminator

Plug

15M with any

IC200ERM002

Modules

750M with all

IC200ERM001

Modules

 

Содержание VersaMax IC754TAN001

Страница 1: ...QuickPanel Control Communication Module Quick Install Guide VersaMax Expansion I O Interface Card IC754TAN001 April 2010 ________________________________________ GFK 2299 ...

Страница 2: ...nformation contained herein does not purport to cover all details or variations in hardware or software nor to provide for every possible contingency in connection with installation operation or maintenance Features may be described herein which are not present in all hardware and software systems GE Intelligent Platforms assumes no obligation of notice to holders of this document with respect to ...

Страница 3: ...ovider ip ge com Technical Support If you have technical problems that cannot be resolved with the information in this guide please contact us by telephone or email or on the web at www ge ip com support Americas Online Technical Support www ge ip com support Phone 1 800 433 2682 International Americas Direct Dial 1 780 420 2010 if toll free 800 option is unavailable Technical Support Email suppor...

Страница 4: ...emea ip ge com Customer Care Email customercare emea ip ge com Primary languages of support English French German Italian Czech Spanish Asia Pacific Online Technical Support www ge ip com support Phone 86 400 820 8208 86 21 3217 4826 India Indonesia and Pakistan Technical Support Email support cn ip ge com China support jp ip ge com Japan support in ip ge com remaining Asia customers Customer Care...

Страница 5: ... environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Note Any chang...

Страница 6: ......

Страница 7: ... 7 Introduction 1 Related Documents 1 Description 2 Indicators 3 Expansion Bus Connector 3 Installing a Communication Module 4 Connecting the Expansion Cable 6 Terminator Plug 7 Differential Inter Rack Connection IC200CBL601 602 615 7 General Specifications 9 Product Certification 10 ...

Страница 8: ...ersaMax Expansion I O Interface Card installed in a QuickPanel Control a GE or user supplied cable and mating connectors and an Expansion receiver module installed at the head end of each VersaMax remote expansion module rack Configuration of the VersaMax Expansion I O interface card in the QuickPanel Control is accomplished using Proficy Machine Edition For a complete description of the features ...

Страница 9: ...sion I O Interface Card is shown below It provides a host connector that connects the Interface Card with your QuickPanel Control operator interface The expansion bus cable is connected to the VersaMax Expansion I O Interface Card through the Expansion connector An LED indicator displays the status of the Interface Card ...

Страница 10: ...tion ON Blinking Interface Card is communicating with the Expansion Rack EXP TX OFF Interface Card is not communicating with the Expansion Rack Expansion Bus Connector The 26 pin female D shell connector on the front of the VersaMax Expansion I O Interface Card is the expansion port for connecting to an Expansion Receiver Module There are two types of Expansion Receiver Modules Isolated IC200ERM00...

Страница 11: ...Expansion I O Interface Card 4 Installing a Communication Module Warning Always use anti static precautions when accessing the mating connector or the interior of the unit Note The 6 model QuickPanel is shown Other models are similar ...

Страница 12: ...into the mating connectors on the back of the unit Caution Be sure to properly align pins in the dual connector upon insertion to avoid damage to the card or the QuickPanel Control unit 4 Install the three screws to secure the card in the unit 5 Close the cover Note To use this card with QuickPanel Control ProficyTM Machine Edition software is required Please refer to the GE Intelligent Platforms ...

Страница 13: ...the cable from the expansion port on the Expansion Transmitter to the Expansion Receivers as shown below QuickPanel Control with Expansion Interface Card IC200CBL601 602 615 Expansion Rack1 Expansion Rack7 PS ERM PS ERM Terminator Plug 15M with any IC200ERM002 Modules 750M with all IC200ERM001 Modules ...

Страница 14: ...the last Expansion Receiver Differential Inter Rack Connection IC200CBL601 602 615 2 3 5 6 8 9 12 13 16 17 20 21 24 25 7 23 1 FRAME FRAME RIRQ RIRQ RUN RUN RERR RERR IODT IODT RSEL RSEL IOCLK IOCLK 0V 0V SHLD PIN 26 pin Male Variable See Maximum Cable Length table 2 3 5 6 8 9 12 13 16 17 20 21 24 25 7 23 1 FRAME FRAME RIRQ RIRQ RUN RUN RERR RERR IODT IODT RSEL RSEL IOCLK IOCLK 0V 0V SHLD PIN 26 pi...

Страница 15: ...anhattan CDT M2483 Alpha 3498C or equivalent cable Maximum Cable Length The maximum overall length of the expansion bus depends on type of Expansion Receivers used and the data rate Receiver Type Data Rate Maximum Cable length Any Non Isolated Expansion Receivers IC200ERM002 on the bus 5 Mbits sec max 15 meters 250 Kbits sec default data rate 750 meters default distance Isolated Expansion Receiver...

Страница 16: ... Specifications Environmental Conditions Temperature Operation Storage 0 C to 60 C 40 C to 85 C Humidity 5 to 95 RH non condensing Vibration Operating IEC 68 2 6 10 57Hz 0 012 peak peak displacement 57 500Hz 1 0g acceleration Shock Operating IEC 68 2 27 15g 11ms sine wave ...

Страница 17: ... D UL1604 C UL Certification by Underwriter s Laboratories to UL standard and equivalent CSA standard Explosive Atmospheres Directive European Safety for Hazardous Locations Equipment Group II Category 3 ATEX Certification in accordance with European Directives Refer to Declaration of Conformity and Independent 3rd Party Assessment Certificate Electromagnetic Compatibility Directive European EMC f...