- 19 -
Night mode:
The detector generates an alarm signal or message when
activated by a person walking in front of it.
Remote test:
The control panel monitors the detector’s sensor and
associated on-board signal processing circuitry.
Self test:
The detector itself monitors the sensor and associated on-board
signal processing circuitry.
Technical fault (TF):
The fault signal or message that is generated on the
AM relay when the detector suffers a fault.
Walk test:
An operational test done by the installer to see if the equipment
will generate an alarm.
11. Technical specifications
Input power
9 VDC to15 VDC (12 Vnominal)
Peak-to-peak ripple
2 V (at 12 VDC)
Current consumption:
Normal operation
20 mA
Alarm
24 mA
Maximum
34 mA
Control input voltage
Low 0 to1.5 VDC
(terminals 10-11-12)
High 3.5 to 15 VDC
Mounting height
Min 1.8 m, max 3.0 m
(Min 5.90 ft., max 9.84 ft.)
Target speed range
10 cm/sec to 4 m/sec
(4 in./sec to 13 ft./sec)
Alarm relay
Optical relay is immune to magnetic influence
Alarm output
80 mA at 30 VDC max.
Tamper output
80 mA at 30 VDC max.
Trouble output
80 mA at 30 VDC max.
Alarm time
3 sec
Detector start-up time
70 sec
Operating temperature
-10°C to +55°C
(14°F to 130°F)
Relative humidity
Max. 95%
Dimensions (H x W x D)
175 x 93 x 66 mm
(6.88 x 3.66 x 2.60 in.)
Weight
275 g (9.70 oz.)
Number of curtains
11 at 20 m and 1 at 60 m
(11 at 65.6 ft. and 1 at 197 ft.)
Viewing angle
86° at 20 m and 3° at 60 m
IP/IK rating
IP30 IK02