49-2000930 Rev. 2
11
INST
ALLA
TION PREP
ARA
TION
Installation Preparation - UVC 9420
CABINET PREPARATION
CL
CL
7-5/8”
18-1/2” Min.
15”
FRONT VIEW
SIDE VIEW
CABINET STRUCTURE
Ŷ
It is required two 2 x 4 horizontal studs separated
by 39” as part of the cabinet. They must be firmly
secured to the cabinet structure.
Ŷ
The cabinet bottom must be made from a wooden
surface ¾” minimum thickness.
WARNING
Make sure the studs and cabinet
bottom surface are firmly secured and able to
withstand 100 pounds.
2" Min.
2" Min.
39" Between
Studs
CUSTOM CABINET FRAME
Ŷ
The custom canopy or cabinet must have a
rectangular opening to accommodate the custom
hood insert by itself. This opening has the same
size for both a wall installation or an island
installation. Ensure parallelism and levelness of
the cabinet so that it doesn't affect flushness of
the hood with the cabinet.
39"
Front of the
opening
recommended
to be 3” from
cabinet front
Back of
opening
recommended
to be 3” from
back wall
21-1/4"
13" from
bottom of
cabinet to
bottom of
house duct