GE UltraSport Скачать руководство пользователя страница 3

What Is Ultra

Sport

 TM

?

The Ultra

Sport floodlight is the combination of proven

lamp, optical and ballast technology from various lighting
applications packaged together for the first time in a 

state of the

art 

sports lighting design.

The end result is unmatched light output and efficiency with

excellent visibility and color rendering for players, spectators
and color TV broadcasting.

Ultra

Sport floodlights also offer outstanding control of

unwanted glare and spill light pollution. And it offers affordable
optional control features like Instant Hot Restart and System
2

TM

 Bi-Level lighting controls. When you look at all the features

the Ultra

Sport has to offer, you will agree that Ultra

Sport is

light years ahead of the competition.

3

Ultra

Sport

 

TM

 Floodlight

What Does the Ultra

Sport

Floodlight System Mean to

You? . . . 

Fewer Fixtures!

The Ultra

Sport floodlight system significantly  reduces the

number of fixtures required to provide the same required light

levels and uniformity ratios. As a result you get:

Lower installation costs

Lower structural costs

Lower maintenance costs

Less energy consumption

Applications

IESNA Class III to major stadia where premium quality
lighting and excellent glare control is required.

Medium to large indoor arenas.

Large stadia and arenas where color TV recording and
broadcasting will be common, and excellent color rendering
and high vertical plane illumination is required.

Sports fields and arenas where optional instant hot restart is
desired in case of momentary power interruption or large
line dips. This feature can be critical when TV recording and

broadcasting is taking place and revenues
may be at risk if there is a short duration
power loss that could cause an 8 to 12 minute
fixture blackout.

Facilities requiring instant off/on capability
for dramatic theatrical lighting choices.

Other general floodlighting applications
where premium lighting is required from a
high wattage metal halide source.

e

Содержание UltraSport

Страница 1: ...PRODUCT GUIDE GE Lighting Systems Inc The greatest highlight in all of sports e Sport TM Floodlight Ultra ...

Страница 2: ...rnational Soccer Doha Qatar COLLEGE University of Maryland Soccer College Park MD Skidmore College Soccer Saratoga Springs NY Rutgers University Soccer New Brunswick NJ University of Virginia Field Hockey Soccer Charlottesville VA Princeton University Football Princeton NJ Michigan State University Football East Lansing MI Syracuse University Soccer Syracuse NY HIGH SCHOOL Ottowa Hills High School...

Страница 3: ...ficantly reduces the number of fixtures required to provide the same required light levels and uniformity ratios As a result you get Lower installation costs Lower structural costs Lower maintenance costs Less energy consumption Applications IESNA Class III to major stadia where premium quality lighting and excellent glare control is required Medium to large indoor arenas Large stadia and arenas w...

Страница 4: ...with a 4000 degree Kelvin color temperature New Optical Design Atwo piecereflectorconfigurationis utilized featuring a Rear Primary reflector and a Front Secondaryreflector The Rear Primary reflector is made of press molded glass featuring a special high reflectance coating for a mirror like finish and 95 visible light reflectivity The Front Secondary reflector is spun from high quality specular a...

Страница 5: ... the lens of a fixture that uses an unjacketed lamp is broken the escaping ultraviolet radiation can create a potential health risk to players and spectators Because of this risk Ultra Sport floodlight is the first sports lighting fixture to feature a Broken Glass Shutdown Circuit The system continuously senses the integrity of the front door glass In the unlikely event that the lens is broken the...

Страница 6: ...ch 3 2mm thick and is permanently sealed and gasketed to the casing A high temperature gasket seals the front optical Hydro GardTM Filtered Optics The entire optical is sealed so that all thermal air transfer moves through an advanced filtering system with particle trapping chemical absorbing and moisturecontrollingproperties criticalforunjacketedmetal halide lamp life and optimum optical performa...

Страница 7: ...ise optical design limits the amount of vertical spill and light pollution without the use of external visor louver assemblies that increase wind loading and structure costs Optional internal cutoff skirts are available and provide direct cutoff of the arc tube at 15 degrees above the floodlight s center aiming point for optimum glare control without the high losses normally associated with extern...

Страница 8: ...from the mechanical support and is made by connecting the spade ended lamp leads to the socket terminals and tightening with a screwdriver 8 GE is Sports Lighting e Metal Halide Metal Halide 2000 Watt Double Ended 1500 Watt Double Ended GE Lamp Number MQI 2000 T9 40 MQI 1500 T8 40 Catalog Number OSRAM Sylvania M2000T9 DE M1500 T9 DE ANSI Designation U134 U133 Burning Position Horizontal 4 Degrees ...

Страница 9: ...ce light levels The ballast circuit will reliably start and stabilize a nominal lamp in ambient temperatures down to 29 degrees C The unit is rated for operation in up to 40 degree C ambient temperatures Ballast Maintenance Electrical access is achieved from the rear of the fixture without any adjustment to the aiming required The rear housing cover is held in place by four captive corrosion resis...

Страница 10: ... capable of withstanding wind forces equal to 125 MPH with a 1 3 gust factor without misalignment of the floodlights Aiming Simply open the rear re lamping door and align the lamp s quartz shutoff tip with the front glass crosshair and target Once these three points are aligned tighten the trunnion bolts Because all access to maintain the Ultra Sport floodlight is from the rear the aiming never ne...

Страница 11: ... Stadium Oval with Internal Glare Control Skirts NEMA 4X2 M01 Medium Oval without Internal Glare Control Skirts NEMA 4X2 M02 Medium Oval with Internal Glare Control Skirts NEMA 4X2 W01 Wide Oval without Internal Glare Control Skirts NEMA 5X3 W02 Wide Oval with Internal Glare Control Skirts NEMA 5X3 WW1 Extra wide oval without Internal Glare Control NEMA 5X4 WW2 Extra wide oval with Internal Glare ...

Страница 12: ...OLP 2518B 7 97 5M GELS TM Trademark of General Electric Company Hendersonville NC 28793 4506 e GE Lighting Systems Inc Sport TM Floodlight Ultra ...

Отзывы: