Step 6
Connect power cable to suitable supply in accord-
ance with all applicable codes.
A . Insert the lamp terminal into the
socket terminal (a) at both ends of the
lamp and torque screws to 20 in. lbs.
B . Slide the lamp ends into the sockets.
LAMP REPLACEMENT
C . Latch the lamp retainers (c).
D . Close and rebolt the relamping door.
Tighten bolts to 50 in. lbs. torque.
Caution: Do not touch quartz tube lamp with bare
hands! If lamp is handled, finger prints, grease or oils
should be removed from the lamp with isopropyl alcohol.
This will remove material which cause whitish spotting
and premature lamp failure. Dry lamp carefully with
cotton or clean cloth.
PERIODIC CLEANING WHEN RELAMPING:
INTERNAL:
Should the internal reflector system require cleaning,
use only non-abrasive, neutral (pH 6-8) cleaner contain-
ing no chlorinated or aromatic hydrocarbons.
Rinse clean and wipe dry.
EXTERNAL:
Clean front glass with a mild soap and water solution,
rinse clean and wipe dry.
NOTICE:
Drain holes are provided in the proper
locations for customary mounting positions. If
floodlight is to be aimed up above the horizontal,
it is necessary to punch out the two knockouts in
the rear ballast cover and plug the three front
housing drain holes with a suitable material such
as silicone RTV.
INSTALLATION CLEANING:
DO NOT CLEAN INTERNAL OPTICAL SYSTEM
The Ultra
M
Sport floodlight has been specially re-
cleaned at the factory. Field cleaning of the internal
optical system during installation is not recommended.
EXTERNAL CLEANING
Initial cleaning of the outside of the glass lens may
be required to ensure optimum optical efficiency.
Clean front glass with a mild soap and water
solution rinse clean and wipe dry.
CLEANING INSTRUCTIONS AND CAUTIONS
After positioning luminaire, tighten all mounting
hardware.
Step 5
Optical Sight:
A . Rotate sight into vertical
position.
B . Align the reference
mark of top of reflector
flange with notch in
sight for proper aiming.
Base Sight
A. Rotate front and back
sight into vertical
position.
B. Align the two sighting
holes for proper aiming.
Step 4 — LUMINAIRE AIMING
Two sighting systems are provided for your convenience.
Use the sight system which is most easily accessed.
CAUTION
Risk of burn
•
Allow lamp/fixture to cool before
handling
REMOTE BALLAST MOUNTING
See below illustration for bolt spacing and bracket
minimum spacing.
Содержание Ultra Sport GRH-5736F
Страница 2: ......
Страница 3: ...REMOTE BALLAST MOUNTING See below illustration for bolt spacing and bracket minimum spacing ...
Страница 4: ......