background image

Electrical Connections

White (-)

Cap wires

1

2

Connect LED strips using in-line (IDC) connectors or
twist-on wire connectors.

Must cap all exposed wires with appropriate wire
connectors.

Red (+)

To Tetra LED System

To power 
supply

Black or blue (-)

Red (+)

Black or blue (-)

White (-)

Red Stripe (+)

Power
Supply

3

4

Run a wire from the power supply to each channel
letter and connect to the first LED module on the
strip.

Connect the red stripe wire (+) of the LED strip to
the red wire (+) of the power supply. Connect the
white wire (-) of the LED strip to the black or blue
wire (-) of the power supply.

NOTE:

All electrical connections should be made

within the letter.

Must be used with

Tetra

® 

12 Volt Power

Supplies

.

Retrofit Instructions

1.

(Existing Signs Only)

Prior to installation, survey the site for information regarding  power and accessibility inside and outside the building.  Ensure 

that the branch circuit supplying  the existing transformer or ballast will be within the voltage ratings of the new LED power supply, and have
a current rating not exceeding 20A, or that permitted by applicable local, state, or country electrical codes (whichever is less).

(Existing Signs Only)

Remove the existing lighting equipment to be replaced, such as neon tubing or fluorescent tubes; and associated 

transformers and ballasts. Care should be taken not to break the existing neon or fluorescent tubes.

NOTE:

Follow all federal and local regulations when disposing of neon tubing, fluorescent tubes, transformers and ballasts.

(Existing Signs Only)

If removal of the existing lighting equipment eliminates the disconnect switch, as required by applicable local, state, or

country electrical codes; a new disconnect switch must be installed.

(Existing Signs Only)

Make sure the removal of lighting equipment does not compromise the integrity of the sign body (i.e. water intrusion). Fill in 

all holes 0.5 in. (13 mm) or smaller with the appropriate amount of rated caulk or sealant . For holes greater than 0.5 in. (13 mm), use an aluminum 
or zinc coated steel patch with rivets and sealant .

(Existing Signs Only

) A clean and dry mounting surface ensures optimum adhesion if the self-adhesive method of mounting is chosen.  Follow 

the manufacturer

’s

directions when using a non-oil based solvent, such as rubbing alcohol to clean the surface area where you intend to mount 

the module.  Before installing, ensure the surface is dry.
Using the layout guidelines above, determine required number of LED modules required to illuminate the sign.
A Tetra

® 

12VDC Class 2 Power Supply, as listed below, must be used with this retrofit kit. Using the Maximum Loading chart below, determine the

number of Tetra

® 

Class 2 Power Supplies required to power the number of LED modules required to illuminate the sign, so as not to overload 

the Tetra

® 

Class 2 Power Supply chosen.

Follow the instructions above to properly mount the LED modules.
Connect the DC output of the power supply to the LED modules using the Electrical Connections instructions above.

2.

3.

4.

5.

6.
7.

8.
9.
10. Connect the power unit to the supply in accordance with the applicable local, state, and country electrical codes, and the instructions found in the 

power supply installation guide.

11. If required, the disconnect switch shall be installed by qualified personnel, in accordance with applicable   local, state, and country electrical codes.

Red Stripe (+)

Содержание Tetra PowerMAX GEPM71-W1

Страница 1: ...tion against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the use...

Страница 2: ...n any of the modules Remove tape backing and stick LED modules into place Continue until you have reached the end of the strip 4 5 6 Use rivets screws or silicone to secure at least every fifth LED module within the channel letter Use 6 M3 or 8 M4 pan headed metal screws 1 8 inch 3 2 mm rivets or silicone Drill a 1 4 6 4 mm hole near the LED strip and grommet the hole for supply wire access Clean ...

Страница 3: ...onnect switch as required by applicable local state or country electrical codes a new disconnect switch must be installed Existing Signs Only Make sure the removal of lighting equipment does not compromise the integrity of the sign body i e water intrusion Fill in all holes 0 5 in 13 mm or smaller with the appropriate amount of rated caulk or sealant For holes greater than 0 5 in 13 mm use an alum...

Страница 4: ...sign enclosure This will allow for uniform backlighting of the sign and will provide simple mounting for the Tetra LED system A best practice for the supply wire at the point at which it is brought into the sign is to have a drip loop on the inside of the letter to keep water from collecting on the Tetra LED strip These products are not required to be enclosed or protected from weather Specificati...

Отзывы: