background image

LED Driver

Wire connections

Cap all unused wires

Refer to the LED Driver Installation Instructions for 

more information on connecting the LED Driver.

Electrical Connections

1

2

3

4

Strip the ends of the wire 1/2-inch (13 mm) on the 

modules (white and red) of adjacent columns that 

you want to connect.
Use UL approved wire connectors (twist-on or 

in-line connectors) and 18 AWG (0.82 mm

2

) wire to 

connect the corresponding wires.
Strip the end of the wire 1/2-inch (13 mm) on the 

first column of modules and connect to the output 

of the LED Driver. Output connections must be 

red-to-red and white-to-black.

Remote Mounting Distance

Loading Chart

Troubleshooting

Symptom
Row of modules does not light

All modules do not light
Individual modules do not light
Modules are dim

• Check wire connections to LED Driver to ensure red-to-red and white-to-white connections.

• Check row-to-row polarity connections.
• Check input voltage and check LED Driver input/output connections.
• Check wire connection attachment and polarity of wires.
• Ensure the overall  length of modules does not exceed the maximum load for the LED Driver.

• Ensure the length of the supply wire is equal to or below the recommended remote mounting  

  distance (see remote mounting distance chart above).

Solution

LED Driver

Minimum Loading

Maximum Loading

79045 (GE080/MV/D24T1-A)

1 Module

30 Modules/20 ft. (6.1m)

67825 (GEPS24-100UGL-IP)

1 Module

36 Modules/24 ft. (7.3m)

62189 (GE180/MV/24T1-C)

1 Module

33 Modules/22 ft. (6.7m) per Bank; 66 Modules/44 ft. (13.4m) per Driver

LED Driver

18 AWG/0.82 mm

2

Supply Wire

16 AWG/1.31 mm

2

Supply Wire

14 AWG/2.08 mm

2

Supply Wire

12 AWG/3.31 mm

2

Supply Wire

67825 (GEPS24-100UGL-IP)

62189 (GE180/MV/V24T1-C)

79045 (GE080/MV/D24T1-A)

1-30 ft. (0.3-9.1m)

1-50 ft. (0.3-15.2m)

1-80 ft. (0.3-24.4m)

1-120 ft. (0.3-36.6m)

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, 

and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class [A] RFLD complies with the 

Canadian standard ICES-003. Ce DEFR de la classe [ A ] est conforme á la NMB-003 du Canada.

Note: 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are 

designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment gen-

erates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interfer-

ence to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required 

to correct the interference at his own expense.

www.gelighting.com

GE and the GE Monogram are trademarks of the General Electric Company. All other trademarks are the property of their respective owners. Information provided is subject to 

change without notice. All values are design or typical values when measured under laboratory conditions. GE Lighting is a business of the General Electric Company. © 2016 GE.

ARCH015 (Rev 01/27/16)