NOTE:
When installing power supply, connect to the appropriate sized building breaker or disconnect device for line and neutral
connections, in accordance with local, state or country regulations.
NOTE:
The grounding and bonding of the power supply and overall sign shall be done in accordance with National Electric Code (NEC)
Article 600.
SIGN098-R092911
Power Supply Specifications
GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com
1 - 8 8 8 - 6 9 - 4 3 - 5 3 3
GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. Tetra is a trademark of GE Lighting Solutions, LLC. The GE brand and logo are trademarks of the General Electric Company.
© 2011 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
Performance Data
GEPS12-60
GEPS12-60U
Min
Typical
Max
Min
Typical
Max
Input Voltage (VAC)
90
100-240
264
108
120-277
305
Input Frequency (Hz)
-
50/60
-
-
50/60
-
Input Current (A)
-
-
0.85
-
-
0.61
Output Voltage (VDC)
11.4
12.0
12.6
11.5
12.0
12.5
Output Current (ADC)
0.8
-
5.0
0.8
-
5.0
Output Power (W)
-
-
60
-
-
60
Dimensions
9.5 in. x 1.7 in. x 1.2 in. (240 mm x 43 mm x 30 mm)
Environmental Specifications
Min
Typical
Max
Environmental Operating Temperature Range
-40°C
+25°C
+65°C*
Environmental Humidity (non-condensing)
-
-
95%
Environmental Storage Temperature Range
-40°C
-
+85°C
*Maximum case temperature is 90°C
Conforms to the following standards:
Load per Power Supply
Min
Max
Tetra miniMAX
GEWHMMTS8, GEWWMMTS8
3 modules/1.2 ft. (0.37 m)
150 modules/60 ft. (18.29 m)
GEWHMMS6, GEWWMMS6
3 modules/1 ft. (0.30 m)
120 modules/40 ft. (12.20 m)
GEBLMMS5, GEGLMMS5, GERDMMS5
3 modules/1.2 ft. (0.37 m)
90 modules/36 ft. (10.97 m)
Tetra MAX
GEWHMXTS6, GEWWMXTS6
2 modules/1 ft. (0.30 m)
120 modules/60 ft. (18.29 m)
GEWHMHTS6, GEWWMHTS6
2 modules/1 ft. (0.30 m)
80 modules/40 ft. (12.20 m)
GEWHMXWA5, GEWWMXWA5, GEBLMXWA5,
GEGLMXWA5, GERDMXWA5
3 modules/1.2 ft. (0.37 m)
135 modules/54 ft. (16.46 m)
GERCMXWA6, GEYGMXS6
3 modules/1 ft. (0.30 m)
162 modules/54 ft. (16.46 m)
GERCMXWL6
2 modules/1 ft. (0.30 m)
160 modules/80 ft. (24.38 m)
GERDMXWL6
2 modules/1 ft. (0.30 m)
140 modules/70 ft. (21.34 m)
Tetra PowerMAX
GEWHPMTL5, GEWWPMTL5
2 modules/1.3 ft. (0.41 m)
38 modules/25 ft. (7.62 m)
GEWHPMS2-65K, GEWWPMS2-30K
2 modules/1 ft. (0.30 m)
50 modules/25 ft. (7.62 m)
Tetra PowerStrip
GEWHSSP3-65K, GEWWSSP3-41K
1 module/1 ft. (0.30 m)
16 modules/16 ft. (4.88 m)
Maximum Remote Mounting Distance
18 AWG
(0.82 mm
2
)
16 AWG
(1.31 mm
2
)
14 AWG
(2.08 mm
2
)
12 AWG
(3.31 mm
2
)
10 AWG
(5.27 mm
2
)
8 AWG
(8.35 mm
2
)
Tetra miniMAX
30 ft./9.1 m
50 ft./15.2 m
80 ft./24.4 m
120 ft./36.6 m
-
-
Tetra MAX
30 ft./9.1 m
50 ft./15.2 m
80 ft./24.4 m
120 ft./36.6 m
-
-
Tetra PowerMAX
GEWHPMTL5, GEWWPMTL5
30 ft./9.1 m
50 ft./15.2 m
80 ft./24.4 m
120 ft./36.6 m
-
-
GEWHPMS2-65K,
GEWWPMS2-30K
15 ft./4.5 m
20 ft./6.1 m
30 ft./9.1 m
60 ft./18.2 m
-
-
Tetra PowerStrip
30 ft./9.1 m
25 ft./7.6 m
35 ft./10.6 m
40 ft./12.1 m
75 ft./22.8 m
100 ft./30.5 m