background image

Tetra

®

 EdgeStrip HO

Installation Guide

4

Height

1 ft. (0.30 m)

2 ft. (0.61 m)

3 ft. (0.91 m)

4 ft. (1.22 m)

5 ft. (1.52 m)

6 ft. (1.83 m)

7 ft. (2.13 m)

Width

1 ft. 

(0.30 m)

EdgeStrip HO: 1 side 

Modules/side: 1

EdgeStrip HO: 1 side 

Modules/side: 1

EdgeStrip HO: 1 side 

Modules/side: 1

EdgeStrip HO: 2 sides 

Modules/side: 1

EdgeStrip HO: 2 sides 

Modules/side: 1

EdgeStrip HO: 2 sides 

Modules/side: 1

EdgeStrip HO: 1 side 

Modules/side: 7

2 ft.

 (0.61 m)

EdgeStrip HO: 1 side 

Modules/side: 1

EdgeStrip HO: 1 side 

Modules/side: 2

EdgeStrip HO: 1 side 

Modules/side: 2

EdgeStrip HO: 1 side 

Modules/side: 4

EdgeStrip HO: 2 sides 

Modules/side: 2

EdgeStrip HO: 2 sides 

Modules/side: 2

EdgeStrip HO: 1 side 

Modules/side: 7

3 ft. 

(0.91 m)

EdgeStrip HO: 1 side 

Modules/side: 1

EdgeStrip HO: 2 sides 

Modules/side: 1

EdgeStrip HO: 1 side 

Modules/side: 3

EdgeStrip HO: 1 side 

Modules/side: 4

EdgeStrip HO: 1 side 

Modules/side: 5

EdgeStrip HO: 1 side 

Modules/side: 6

EdgeStrip HO: 1 side 

Modules/side: 7

4 ft. 

(1.22 m)

EdgeStrip HO: 2 sides 

Modules/side: 1

EdgeStrip HO: 1 side 

Modules/side: 4

EdgeStrip HO: 1 side 

Modules/side: 4

EdgeStrip HO: 2 sides 

Modules/side: 4

EdgeStrip HO: 2 sides 

Modules/side: 4

EdgeStrip HO: 2 sides 

Modules/side: 4

EdgeStrip HO: 2 sides 

Modules/side: 7

5 ft. 

(1.52 m)

EdgeStrip HO: 2 sides 

Modules/side: 1

EdgeStrip HO: 2 sides 

Modules/side: 2

EdgeStrip HO: 1 side 

Modules/side: 5

EdgeStrip HO: 2 sides 

Modules/side: 4

EdgeStrip HO: 2 sides 

Modules/side: 5

EdgeStrip HO: 2 sides 

Modules/side: 5

EdgeStrip HO: 2 sides 

Modules/side: 7

6 ft. 

(1.83 m)

EdgeStrip HO: 2 sides 

Modules/side: 1

EdgeStrip HO: 2 sides 

Modules/side: 2

EdgeStrip HO: 1 side 

Modules/side: 6

EdgeStrip HO: 2 sides 

Modules/side: 4

EdgeStrip HO: 2 sides 

Modules/side: 5

EdgeStrip HO: 2 sides 

Modules/side: 6

EdgeStrip HO: 2 sides 

Modules/side: 7

7 ft. 

(2.13 m)

EdgeStrip HO: 1 side 

Modules/side: 7

EdgeStrip HO: 1 side 

Modules/side: 7

EdgeStrip HO: 1 side 

Modules/side: 7

EdgeStrip HO: 2 sides 

Modules/side: 7

EdgeStrip HO: 2 sides 

Modules/side: 7

EdgeStrip HO: 2 sides 

Modules/side: 7

EdgeStrip HO: 2 sides 

Not Recommended

Design Guidelines

All guidelines are based on a 5 in. (127mm) deep sign 

for Tetra

®

 EdgeStrip High Output. When installing the 

modules, it is typically recommended to install the 

modules across the longest distance to allow for the 

shortest light throw. 

A 2 in. (51 mm) border is 

recommended along the 

perimeter of the sign.

2 inches

1.   (Existing Signs Only) Prior to installation, survey the site for information regarding power and accessibility inside and outside the 

building.  Ensure that the branch circuit supplying the existing transformer or ballast will be within the voltage ratings of the new LED 

power supply, and have a current rating not exceeding 20A, or that permitted by applicable local, state, or country electrical codes 

(whichever is less).   

2.   (Existing Signs Only) Remove the existing lighting equipment to be replaced, such as neon tubing or fluorescent tubes; and 

associated transformers and ballasts. Care should be taken not to break the existing neon or fluorescent tubes.   

NOTE: Follow all federal and local regulations when disposing of neon tubing, fluorescent tubes, transformers and ballasts.

3.   (Existing Signs Only)  If removal of the existing lighting equipment eliminates the disconnect switch, as required by applicable 

local, state, or country electrical codes; a new disconnect switch must be installed.

4.   (Existing Signs Only) Repair and seal any unused openings in the electrical enclosure. Openings greater than 12.7-mm (1/2-in) 

diameter require a metal patch secured by screws or rivets and caulked with non-hardening caulk. Smaller openings may be sealed 

with non-hardening caulk.

5.  Using the layout guidelines above, determine required number of LED modules required to illuminate the sign.

6.  A 24VDC Class 2 Power Supply, as listed below, must be used with this retrofit kit. Determine the number of Power Supplies required 

to power the number of LED modules required to illuminate the sign, so as not to overload the Power Supply chosen.

7.  Follow the instructions above to properly mount the LED modules

8.  Connect the DC output of the power supply to the LED modules using the Electrical Connections instructions above.

9.  Connect the power unit to the supply in accordance with the applicable local, state, and country electrical codes, and the instructions 

found in the power supply installation guide.

10. If required, the disconnect switch shall be installed by qualified personnel, in accordance with applicable  local, state, and country 

electrical codes.

Retrofit Instructions