The luminaire can be installed at a fixed surface with two
brackets.
(See Fig.1)
Step by Step:
1)
Confirm the installation room, and refer to section VI
the size of luminaire.
2)
Install the two brackets to fixed surface with screws
of provided. (Ensuring that the screws don’t touch any
obstructions such as cables, water pipes, etc.)
3)
Fix the luminaire to the two brackets directly.
4)
Adjust luminaire to desirable position.
5)
Refer to section V for installation of lamp.
2. Series connection
Fixture can be connected by two ways, and the maximum
allowable connection quantity is 10 pieces. (See Fig.2)
Notice:
Luminaires suitable for direct mounting on normally
flammable surfaces.
V. MAINTENANCE/ LAMP REPLACEMENT
FAILURE PARTS NEED TO BE REPLACED IF YOU INSPECT
THE LAMP EXTINCT, FLICKING OR CYCLING. ORDER THE
REPLACEMENT
PART
INDIVIDUALLY.
CONTACT
THE
MANUFACTURES FOR THE MAINTENANCE SERVICE.
LAMP REPLACEMENT
Light output is also dependent on burning time of lamp. In
applications where light levels are critical, it may be
desirable to replace lamps before the end of life. Lamp
manufacturer can provide life curve datasheet of light
output
1)
Shut off power.
2)
Carefully remove the diffuser if have.
3)
Use one hand to push the both side of end cap and
another hand release the cover. (See Fig.3)
4)
Turn 90
°
and remove the lamps to be replaced.
5)
Re-install the luminaire in line with the requirements
of qualified lamp.
6)
Restore.
WARNING
Please note the lamp type, wattage shall be same
as the indication of the product label.
Cut off the power before installation, and let lamp
and fixture cool down.
The diffuser is frangible, cannot press hardly.
If lamp is handled, fingerprint, grease or oils should be
removed from lamp with isopropyl alcohol. This will
remove material that will cause whitish spotting, and
premature lamp failure. Dry lamp carefully with cotton or
clean cloth.
GE T5 Starcoat ™ lamp is recommended
VI. PRODUCT INFORMATION
PRODUCT BASIC INFO
Description Lamp & Power
Rating
Voltage
Power
Current Frequency PF
Max Series
Current
Recommended
GE lamp
Size mm
(
L
W
H
)
DMS 08 Series T5 LFL 1x8W
220-240V
~ 0.075A
50/60Hz 0.95
0.85A
F8T5
318
24.5
47
DMS 14 Series T5 LFL 1x14W 220-240V
~
0.13A
50/60Hz 0.95
1.4A
F14W/T5/HE
579
24.5
47
DMS 21 Series T5 LFL 1x21W 220-240V
~
0.11A
50/60Hz 0.95
2A
F21W/T5/HE
879
24.5
47
DMS 28 Series T5 LFL 1x28W 220-240V
~
0.14A
50/60Hz 0.95
1.5A
F28W/T5/HE
1179
24.5
47
In addition to above introduction, we are also providing multiple combinations to customer, including with/without
diffuser, different lamp color temperature, package and accessories. For detail information please contact GE’s sales
team or distribution agency.
PRODUCT DIMENSIONS AND OUTLINES (mm)
Wiring Series connection Coupler Series connection
(Fig. 2)
(
Fig.3
)
GE Lighting Co., Ltd.
No. 88, Lane 1517, Hu Yi Gong Road,
Jiading District, Shanghai, 201802, P.R.C
+86-800-820-9992
www.gelighting.com
(
Fig.1
)