Component/FRU Removal and Replacement
148
T2100-ST1 Treadmill, 110V / T2100-ST2 Treadmill, 220V
2097937-002 Rev G
11 March 2019
Replacing the Emergency Stop Button (ESB)
Tools Required
o
1/8” Allen Wrench
o
¼” Flat Blade Screwdriver
o
2 Pair Long Nose Pliers
o
Grounding Wrist Strap
Approximate time to complete: 30 min
1.
Turn the treadmill main power switch to the OFF position.
2.
Unplug the treadmill plug from the wall receptacle.
3.
Allow the treadmill to discharge for 1 minute.
4.
With a 1/8” Allen wrench, remove the (2) 10-32 screws (Fig.
A) holding the ESB assembly to the fabricated handrail.
Fig. A
Fig. B
5.
With a flat head screwdriver, remove the ESB assembly
from the fabricated handrail (Fig. B).
10-32 Screw
1/8” Allen
Wrench
ESB or STS
Assembly
Fabricated
Handrail
Screwdriver